The Wavecom WCM-RCD is a microprocessor based Residual Current Device Tester or an Earth Leakage Circuit Breaker Tester that meets today’s standards of safety and performance.
The WCM-RCD unit is a very high quality instrument used by professionals to obtain accurate values of protection time whilst a selectable fault current is injected to the earth. RCD trip time can also be easily measured at the power outlet.
It tests all conventional RCD safety switches in electrical installations and extension leads.
The Wavecom WCM-RCD is a well specified RCD tester featuring trip time and trip current testing.
The Wavecom WCM-RCD uses an in-built microprocessor for achieving high accuracy and reliability. It detects a voltage presence and will automatically start and stop the tests. AC voltage measurements between line and earth are measured and displayed before the start of tests. The LED’s display a safety status indication of the mains supply. The test current and phase angles of 0/180 degrees can be easily changed via the main menu. The Wavecom WCM-RCD comes with a 3 year warranty.
– in trip time (expressed in ms) or
– in trip current value (expressed in mA).
This enables 10mA / 30mA / 100mA/ 300mA / 500mA and 650mA Residual Current breakers to be tested irrespective of their type (normal or delayed).
This tester can also be used to test the configuration of the network and the connection of the earthing conductor. The back light, dual colour screen immediately informs you whether the values measured are compliant (blue) or not compliant (red).
Wavecom WCM-RCD Applications:
Performing trip time tests on RCD’s as required by electrical regulation and as detailed in the AS/NZS3760:2010.
Included accessories:
Power lead, RCD tester, Batteries, IEC lead.
Technical Specifications:
1. 3-digit measurement display
2. N or S (delayed) type RCD test, – AC or A (continuous component detection)
3. Operates on a TT neutral and TN system
4. Operating voltage:230V (Ph./N) – 10/+6% 50/60 Hz
5. Cat III 600V
6. Double insulation
– 1 IEC 61010-1
– 2 IEC 61557-6 NF EN 61557-6
– 3 IEC 61236 (EMC)
– 4 Locking and warning signals for 400V network voltage and contact potential >50V
– 5 Operating temperature: -15°C /+45°C
– 6 Storage temperature: -25°C /+70°C
– 7 IP40
– 8 Resistance to mechanical shock:1G
– 9 Weight : 340g
– Dimensions: w=71mm l=210mm h=51mm
– Four 1.5V ‘AA’ batteries
Standard warranty
3 Year