HIOKI LR8431-20 Data Logger | 10-Channel Industrial Testing

$2,900.00 .( $3,190.00 inc. GST )

Add-On Options


For all your equipment calibration needs, visit our MyCalibration website.


Free Delivery on orders over $1000
Shipping time may vary for certain products*

Product Enquiry

If you would like more information regarding this product, simply email us here.

  • This field is for validation purposes and should be left unchanged.
  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.

    Hioki logo

     

    Capture complex electrical and thermal data in real time with the HIOKI LR8431-20, a compact 10-channel data logger designed for Australian conditions.

    Record voltage, temperature, and rotation measurements simultaneously with 10ms speed across all channels. USB and CF card support ensure seamless data transfer and long-term storage. Ready for immediate deployment on motor testing, HVAC efficiency evaluation, and equipment diagnostics.

    3 year warranty

    PDF Download brochure: MEMORY HiLOGGER LR8431, HEAT FLOW LOGGER LR8432

    HIOKI LR8431-20 Data Logger

    Modern electrical systems are becoming increasingly complex. Whether you’re diagnosing a reluctant compressor in an HVAC unit, evaluating an electric vehicle motor, or monitoring temperature distribution across multiple points in a facility, single-point measurements simply don’t tell the full story. You need simultaneous data capture from multiple locations to identify performance bottlenecks, verify efficiency claims, and troubleshoot intermittent faults that refuse to show up on a standard multimeter.

    The challenge is that traditional single-channel loggers force you to make multiple passes, potentially missing transient events or introducing measurement inconsistencies. Modern testing demands the ability to see what’s really happening across your entire system in one decisive test run.

    The 10-millisecond sampling speed across all 10 channels simultaneously means you’re capturing waveforms with genuine temporal fidelity. When diagnosing motor performance during inrush current conditions, evaluating power quality distortions, or measuring rapid temperature fluctuations in HVAC equipment, that 10ms resolution reveals events that slower loggers simply miss. You’re seeing the actual behavior of your equipment, not a smoothed approximation.

    Complete channel isolation is equally critical. The semiconductor relay isolation architecture eliminates inter-channel interference and prevents dangerous ground-loop problems when you’re measuring both voltage and temperature signals simultaneously. This isolation also protects against earth faults—a significant safety advantage when testing in Australian industrial environments where grounding conditions can be unpredictable.

    Data storage flexibility reflects real-world testing realities. For quick diagnostics requiring 30 minutes to a few hours of continuous monitoring, the internal 3.5-megaword memory capacity handles everything you need. But when you’re conducting long-term efficiency studies—evaluating an air conditioning system’s 24-hour performance or monitoring a solar installation’s temperature behavior across seasonal extremes—the CF card support provides industrial-grade storage reliability.

    What sets the LR8431-20 apart is the ability to swap storage media without stopping your test. Imagine monitoring HVAC performance through a complete day-night cycle. Rather than stopping the test or losing continuity, you simply swap out a full CF card for a fresh one, maintaining continuous data acquisition while gaining access to recorded data for immediate preliminary analysis. USB flash drive support ensures your data transfers quickly to your laptop or office computer for detailed analysis and reporting.

    The 10-channel architecture supports diverse measurement types, making the LR8431-20 genuinely flexible across multiple trade applications.

    Voltage measurements span from 100mV to 60V across six selectable ranges, with 5-microvolt resolution at lower ranges. This precision suits everything from low-voltage control circuit diagnostics to mains supply quality assessment. The digital 50/60 Hz filter option eliminates power-line noise contamination, essential for clean readings in Australian industrial environments with substantial harmonic distortion.

    Thermocouple support covers -200°C to 1800°C with seven thermocouple types (K, J, E, T, N, R, S, B) and automatic reference junction compensation. You’re measuring HVAC ductwork temperature, motor winding conditions, industrial oven performance, or battery thermal behavior—the LR8431-20 handles it with professional accuracy. The 0.1°C resolution captures meaningful variations in system behavior.

    Pulse input channels (four dedicated channels with shared ground) count rotation speeds, track mechanical tachometer signals, or monitor pulse-based sensors. Whether logging compressor cycles in refrigeration plant testing or measuring pump rotation in solar thermal systems, pulse measurements integrate naturally into your multi-point test strategy.

    The 4.3-inch color LCD screen isn’t just for show—it’s genuinely useful in the field. Real-time waveform display allows immediate assessment of whether your test is capturing what you need, preventing wasted travel time back to the workshop only to discover setup issues. The bright display performs well even under Australian sunshine, a significant advantage for outdoor solar and climate control testing.

    Compact dimensions (176mm × 101mm × 41mm) and 550-gram weight mean this logger fits genuinely in your test kit alongside other essentials. The included AC adapter handles 100-240V, so you’re never stranded without power, and optional battery pack support (2.5 hours continuous use) provides flexibility for remote site testing.

    The included Logger Utility software transforms data into meaningful analysis on your office computer—numerical calculations, waveform visualization, and straightforward export options for client reporting. No learning curve, no compatibility confusion.

    The HIOKI LR8431-20’s complete channel isolation, accurate reference junction compensation for thermocouples, and noise-resistant measurement circuitry ensure your readings reflect genuine system behavior, not instrument artifacts.

    HVAC System Efficiency Testing: Measure supply and return temperatures across multiple ductwork points simultaneously, log compressor discharge temperature and motor current, monitor humidity fluctuations. Document actual system performance for warranty claims, efficiency disputes, and retrofit planning.

    Electric & Hybrid Vehicle Development: Log motor winding temperature, inverter voltage output, battery current, and mechanical output speed during acceleration events. Capture the transient behavior that validates or challenges performance claims.

    Industrial Motor Diagnostics: Record voltage across all three phases plus load current and bearing temperature. Identify phase imbalance, voltage distortion, and thermal stress patterns that predict failure.

    Solar Thermal System Monitoring: Log collector outlet temperature, storage tank temperature at multiple depths, pump run time (via pulse counting), and flow sensor signals. Validate system efficiency and identify maintenance needs.

    Power Quality Audits: Simultaneous voltage measurement across multiple circuits with 10ms resolution reveals harmonic distortion, voltage sags, and switching transients invisible to standard meters.

    Equipment Performance Validation: Any industrial equipment requiring multi-point simultaneous testing—refrigeration plant commissioning, ventilation system balance, manufacturing process monitoring.

    Basic specifications

    Accuracy guaranteed: 1 year
    Number of channels Analog: 10 isolated channels using scanning input method (M3 mm dia. screw terminal block)
    Pulse: 4 channels (All pulse inputs share common ground with the main unit)
    Measurement parameters Voltage : ±100 mV to ±60 V, 1-5V f.s. 6 ranges, Max. resolution 5µV
    Temperature (thermocouples) : -200 ˚C to 1800 ˚C (depend on the sensor), 1 range (K, J, E, T, N, R, S, B), Max. resolution 0.1 ˚C
    Temperature (Pt 100 sensor) : cannot use
    Humidity : cannot use
    Totalized pulses : 0 to 1000M pulse, 1 range (No-voltage ‘a’ contact, open collector or voltage input), Max. resolution 1 pulse
    Rotation count : 0 to 5000/n (r/s) f.s. 1 range (No-voltage ‘a’ contact, open collector or voltage input), Resolution 1/n (r/s) Note: n = pulses per rotation (1 to 1,000)
    Max. allowable input DC 60 V (Analog input), DC -5 V to 10 V (Pulse input)
    Max. rated voltage to earth AC 30 Vrms, DC 60 V (Upper limit voltage that does not cause damage when applied between input channel and chassis, and between each input channels)
    Recording intervals 10 ms to 1 hour, 19 selections (All input channels are scanned within each recording interval.)
    Selectable filters 50 Hz, 60 Hz, or OFF (digital filtering of high frequencies on analog channels)
    Memory capacity Internal storage: 3.5 M-words, External storage: CF card or USB memory stick (only the HIOKI CF card is guaranteed for correct operation)
    External interface USB 2.0 mini-B receptacle ×1; Functions: Control from a PC, Transfers files from the installed CF card to a PC (cannot transfer files from the connected USB memory stick to a PC via USB communication), Data copy between CF card and USB memory stick
    Display 4.3-inch WQVGA-TFT color LCD (480 × 272 dots)
    Functions Save data to the CF card or USB memory stick in real time, Numerical Calculations, etc.
    Power supply AC adapter Z1005: 100 to 240 VAC (50/60 Hz)
    Battery pack 9780: Continuous use 2.5 hours
    12 V DC supply: 10 to 16 V (please contact HIOKI distributor for cable; less than 3 m/9.84 ft cable length)
    Dimensions and mass 176 mm (6.93 in) W × 101 mm (3.98 in) H × 41 mm (1.61 in) D, 550 g (19.4 oz) (Battery pack 9780 not installed)
    Included accessories Measurement Guide ×1, CD-R (Instruction manual PDF, Logger Utility Instruction Manual PDF, Data acquisition application program Logger Utility) ×1, USB cable ×1, AC adapter Z1005 ×1

    Combination status with LabVIEW or MATLAB script

    Compatible models LabVIEW MATLAB script
    LR8431-20 N/A N/A

    Q: Can I measure both voltage and temperature from the same circuit without safety risks?

    A: Absolutely. The complete channel isolation between all 10 analog inputs eliminates the ground-loop hazards that plague standard equipment. You can simultaneously monitor mains voltage on one channel and thermocouple temperature on another with zero crosstalk or earth fault risk. This isolation also protects your equipment if a fault develops between measurement points.

    Q: How does the 10ms sampling speed compare to standard data loggers?

    A: Most portable loggers sample at 100ms or 1-second intervals—fast enough for gradual temperature changes but too slow to capture waveform detail or transient events. At 10ms, the LR8431-20 captures 100 data points per second across all channels simultaneously. You’ll see inrush current peaks, voltage sags, rapid temperature spikes, and mechanical vibration effects that slower loggers smooth away completely.

    Q: What happens when internal memory fills? Can I swap storage without stopping the test?

    A: Internal memory holds 3.5 megawords, sufficient for hours of testing depending on sampling interval. When you transition to CF card or USB recording for longer tests, you can swap media without interrupting measurement—essential for continuous 24-hour monitoring. Just ensure the new media is inserted within two minutes of removal to maintain continuity.

    Q: Which thermocouple types does it support, and why would I choose one over another?

    A: All seven common types: K (widest range, industrial standard), J (excellent linearity, excellent at lower temps), E (sensitivity for precise measurement), T (cold junction stability), N (stability at high temperature), R/S (high-temperature specialist, precious metal), B (extreme temperature measurement). For Australian HVAC and industrial work, K-type dominates due to durability and availability. Your distributor can advise on specific application requirements.

    Q: Is the battery pack sufficient for field work without AC power?

    A: The optional 9780 battery pack provides 2.5 hours continuous operation, adequate for most field diagnostics. For extended remote site testing, the included AC adapter with 100-240V input accommodates Australian power infrastructure, and 12V DC supply options (via optional cable) suit generator or solar-powered temporary setups.

    Q: What makes HIOKI CF cards different from standard compact flash cards?

    A: HIOKI CF cards are manufactured to strict industrial specifications for reliable long-term storage of critical test data. Standard consumer CF cards offer no guarantees for data integrity in industrial environments or extended storage periods. For your professional reputation, HIOKI media investment is worthwhile assurance.

    Q: How does the Logger Utility software handle data export for client reporting?

    A: Captured data imports directly into Logger Utility on Windows or Mac. You can view waveforms, perform numerical calculations (averages, peaks, totals), generate graphs, and export results in standard formats for professional client reports. No steep learning curve—the interface reflects straightforward measurement thinking.

    Need help? Call our support team 1800 358 531