HIOKI PW3360-20/500 Power Logger Kit – 500A 3-Phase Energy Audits

$4,800.00 .( $5,280.00 inc. GST )


For all your equipment calibration needs, visit our MyCalibration website.


Free Delivery on orders over $1000
Shipping time may vary for certain products*

Product Enquiry

If you would like more information regarding this product, simply email us here.

  • This field is for validation purposes and should be left unchanged.
  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.

    Hioki logo

    Professional-grade power logger with integrated 500 A clamp sensors, hard case, and complete field kit. Simultaneously monitor voltage, current, and power demand across single and 3-phase circuits.

    Store months of data on SD card for compliance reporting, energy audits, and performance verification. Australian-compliant testing solution ready to use straight out of the box.

    PDF Download Brochure: CLAMP ON POWER LOGGER PW3360

    HIOKI PW3360-20/500 Clamp-On Power Logger Kit – 500A 3-Phase Energy Auditing & Compliance Documentation

    Electrical contractors, maintenance teams, and facility managers across Australia face a critical challenge: proving electrical system performance and energy efficiency without disrupting operations. Traditional handheld meters give you a snapshot—but what happens over time?

    How do you document power demand patterns for an entire site? How do you prove that solar installations are performing to specification, or that industrial equipment is running efficiently? Without documented evidence, you’re left guessing about power quality, demand spikes, and energy waste. You need continuous, site-wide monitoring that creates audit trails for compliance, diagnosis, and optimization—without requiring dedicated IT infrastructure or constant manual readings.

    SOLUTION OVERVIEW

    The HIOKI PW3360-20/500 Kit delivers continuous, automated power monitoring that transforms how you approach energy audits, compliance documentation, and system diagnostics. Instead of snapshot readings, you capture detailed power data across hours, days, or weeks—stored directly on SD cards for later analysis and reporting. The integrated 500 A clamp sensors eliminate the need for separate equipment orders; everything you need is included and ready for deployment on Australian electrical systems.

    This compact 550 g logger fits into confined plant rooms and ceiling cavities, making it practical for real-world job sites where access is limited. The QUICK SET feature walks you through 3-phase connections step-by-step, preventing the wiring mistakes that compromise data accuracy. HIOKI’s robust design handles typical Australian site conditions—industrial vibration, temperature fluctuations, and high-use environments—while maintaining ±0.3% measurement accuracy.

    Whether you’re proving solar system performance under AS/NZS 5033, documenting industrial energy baseline for efficiency programs, or verifying power factor compliance across facility circuits, the PW3360-20/500 provides defensible, traceable evidence.

    KEY BENEFITS & FEATURES

    • Continuous Multi-Phase Monitoring That Captures Real Patterns Unlike spot checks, the PW3360-20/500 logs voltage, current, power, and demand simultaneously across three channels. You see actual consumption patterns, not averages. For solar installers verifying system integration into grid-connected properties, this means documenting instantaneous power injection and demand interaction—critical data under AS/NZS 5033. For facility managers, it reveals demand peaks that inform capacity planning and efficiency opportunities.
    • 500 A Clamp Sensors—Everything Included, No Separate Orders The kit includes full-capacity 9661 clamp sensors up to 500 A, eliminating the frustration of incomplete equipment and unexpected costs. You mount the logger once, then monitor multiple circuits or phases without repositioning the base unit. The multicolored clips and spiral tubes keep everything organised on site, reducing setup time and improving measurement accuracy.
    • 3-Phase Capability for Real Australian Industrial Sites Single-phase equipment matters, but most Australian industrial and commercial properties run 3-phase circuits. This logger simultaneously captures all three phases, giving you complete system visibility. No guesswork. No jumping between measurements. Complete load distribution data in one session.
    • Data Logging That Creates Compliance Audit Trails Store months of raw data on the included 2 GB SD card. Access real-time and historical graphs on the 3.5″ color display, or transfer data to your computer via USB/LAN for professional reporting and analysis. The GENNECT One SF4000 software (included) transforms raw data into graphs and reports suitable for compliance documentation, client handover, and internal analysis.
    • Engineered for Australian Field Conditions At just 550 g, it’s portable enough to carry between job sites yet robust enough for harsh industrial environments. The compact design (180 mm × 100 mm × 48 mm) fits into spaces where bigger equipment can’t reach—crucial in retrofit projects and confined plant rooms. Battery operation (6 hours continuous) or AC power gives you flexibility on sites with variable power availability.
    • Wiring Check & QUICK SET—Eliminates Setup Errors Three-phase connections are straightforward once you understand the logic, but mistakes happen. HIOKI’s on-screen QUICK SET guides you through connections, and the wiring check function flags errors before measurement begins. This small feature has prevented countless days of wasted effort from corrupted data.

     APPLICATIONS & USE CASES

    Solar Installation Performance Verification (AS/NZS 5033 Compliance) Installers must document system performance and grid interaction. The PW3360-20/500 logs real-time power injection, voltage stability, and phase balance over days or weeks—providing the evidence of compliant operation required by standards and insurance. Compare baseline grid consumption against post-installation data to prove system contribution and customer benefit.

    Industrial Energy Audits & Efficiency Programs Facility managers identify where energy is wasted—often in demand peaks and power factor issues. This logger captures demand profiles across all phases over extended periods, revealing patterns that spot checks miss. Armed with actual data, you negotiate better supply contracts, justify equipment upgrades, or prove energy savings post-efficiency intervention.

    Power Quality Investigation on Critical Circuits When equipment fails prematurely or behaves erratically, power quality often plays a hidden role. Log voltage stability, frequency variation, and harmonic content (with PW3360-21 option) to diagnose whether site conditions are contributing to failures. This data supports warranty claims and informs maintenance strategies.

    Load Distribution & Electrical Compliance Testing Commercial buildings must prove balanced load across phases under AS/NZS 3000. The simultaneous 3-phase logging shows actual distribution and identifies circuits contributing to imbalance, enabling remedial rewiring or load rebalancing documentation.

    Preventive Maintenance & Baseline Establishment Before critical equipment fails, establish a power consumption baseline. Regular logging detects gradual changes—a sign of motor degradation, bearing wear, or control system drift—allowing planned maintenance before failure.


    We’re not just resellers; we’re Australian electrical professionals who understand your challenges. We stock this kit because we use it on our own projects—energy audits, compliance documentation, solar integration verification, and industrial troubleshooting.

    Unlike general tool suppliers, we know the Australian electrical standards that matter to your work: AS/NZS 3000, AS/NZS 5033, AS/NZS 3760. We don’t sell you a kit and hope you figure it out. Our team provides guidance on application selection, troubleshooting, and data interpretation.

    We offer fast Australian delivery and local technical support. If you need advice on sensor selection, software integration, or how to structure your testing methodology, we’re here. We’ve invested in HIOKI relationships to ensure you get genuine products, legitimate warranties, and access to firmware updates and software tools.

    The PW3360-20/500 is an investment in documentation, compliance, and confidence. We want to ensure it delivers results on your specific projects.

    Basic specifications

    Accuracy guaranteed: 1 year
    Measurement line & number of circuits 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
    Measurement items Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input
    [PW3360-21 only]: Harmonic voltage level, harmonic current level, harmonic power level, content percentage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th order
    Voltage ranges 600 V AC (Effective measurement range: 90.00 V to 780.00 V)
    Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use),
    50.000 mA to 5.0000 A AC (Leak clamp on sensor only)
    Power ranges 300.00 W to 9.0000 MW (depends on voltage/current combination and measured line type)
    Basic accuracy Voltage : ±0.3% rdg. ±0.1% f.s
    Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
    Active power : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1)
    Display update rate 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
    Save destination SD memory card, or internal memory at real time
    Data save interval 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
    Save items Measurement value save: Average only / Average, Max./Min. value, [PW3360-21 only]: Harmonic data save: Average only / average, max./min. value in binary format, Screen copy: BMP form (saved every 5 min. at minimum interval time), Waveform save: Binary waveform data
    Interfaces SD/SDHC memory card
    LAN 100BASE-TX: HTTP server function
    USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
    Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal
    Functions Connection check, Quick Set navigation guide, clock, pulse input
    Power supply AC Adapter Z1006: (100 to 240 V AC, 50/60 Hz), 40 VA (including AC adapter)
    Battery Pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 6 hours of continuous use (with back light off)
    Dimensions and mass 180 mm (7.09 in) W × 100 mm (3.94 in) H × 48 mm (1.89 in) D, 550 g (19.4 oz) without PW9002
    180 mm (7.09 in) W × 100 mm (3.94 in) H × 67.2 mm (2.65 in) D, 830 g (29.3 oz) with PW9002
    Included accessories Voltage cord L9438-53 ×1 set, AC adapter Z1006 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip ×1 set: red, yellow, blue, white/two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5, Application Software CD (SF4000 GENNECT One) ×1

    • 3-phase power monitoring

    Q: What’s the difference between the PW3360-20 and PW3360-21? A: The PW3360-20 (this kit) measures voltage, current, power, and demand—sufficient for 95% of energy audits and compliance checks. The PW3360-21 adds harmonic analysis to the 40th order, useful for power quality diagnosis on sensitive equipment. For most Australian trade work, the -20 model is the right choice.

    Q: Can this measure 3-phase circuits without moving the logger? A: Yes. The logger has 3 voltage inputs and 3 current inputs, allowing simultaneous measurement across all three phases. This is why the kit includes three 500 A clamp sensors—you connect them once and monitor continuously.

    Q: How long can the included 2 GB SD card record? A: It depends on your logging interval. At 1-minute intervals, you get approximately 4 weeks of data. At 10-minute intervals, roughly 40 weeks. The point is you’re not constantly offloading data—set it up, let it run for the duration you need, then download everything at once.

    Q: Is the data format proprietary, or can I work with it in Excel? A: HIOKI provides the GENNECT One SF4000 software (included on CD) that displays and exports data. You can generate professional reports, or export raw CSV data for further analysis. Most users find the built-in graphing sufficient for compliance documentation.

    Q: Does this kit come with everything, or do I need to order sensors separately? A: It comes with everything. The three 500 A clamp sensors are included, along with voltage cord, USB cable, AC adapter, SD card, carrying case, and software. You can use it immediately out of the box.

    Q: What’s the warranty, and does it cover damage from typical job site conditions? A: HIOKI provides a 3-year product warranty against manufacturing defects. Like any electronic instrument, it needs reasonable care (protection from dropped impacts, submersion, extreme temperatures). We recommend using the included hard case for transport between job sites.

    Need help? Call our support team 1800 358 531