KYORITSU 6205 Portable Appliance Tester

$1,000.00 .( $1,100.00 inc. GST )


For all your equipment calibration needs, visit our MyCalibration website.


Free Delivery on orders over $1000
Shipping time may vary for certain products*

Product Enquiry

If you would like more information regarding this product, simply email us here.

  • This field is for validation purposes and should be left unchanged.
  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.

    Kyoritsu KEW 6205 portable appliance tester for fast, reliable electrical safety testing. Ideal for professionals. Fast, reliable delivery.

     

        Kyoritsu-6205-Datasheet

        Kyoritsu-6205-User-Manual

     

    KYORITSU 6205 Portable Appliance Tester – for Australia

    ・Complies to AS/NZS 3760
    ・Battery operated
    ・PASS / FAIL result
    ・Color status back light
    ・10 mA & 30 mA RCD test (Isolation transformer built-in)
    ・Memory function up to 999 data
    ・Printer output

     

    Ensure comprehensive electrical safety compliance with the Kyoritsu KEW 6205, a high-performance portable appliance tester (PAT). Engineered for electricians, maintenance teams, and safety inspectors, this device simplifies the process of verifying the safety of Class I and Class II appliances. Its robust design and straightforward operation make it an essential tool for ensuring workplace safety and meeting regulatory standards.

    The KEW 6205 streamlines testing procedures with its pre-programmed test sequences. Simply select the appliance class, and the instrument automatically runs the required tests: Earth Bond, Insulation, and Polarity. The large, backlit LCD display provides clear pass/fail indications, eliminating guesswork and reducing the time spent on each test. This efficiency is critical for professionals managing a high volume of assets, allowing for rapid and accurate assessment across any site.

    Designed for portability and ease of use in the field, this electrical safety testing device is lightweight yet durable. It operates via batteries, providing complete freedom from mains power during testing. The KEW 6205 also includes a lead null function to zero out the resistance of the test leads, ensuring precise and reliable Earth Bond measurements every time. For any professional who values accuracy, efficiency, and dependability, the Kyoritsu KEW 6205 is the trusted solution for portable appliance testing.

    Key Features:

    • Pre-programmed test sequences for Class I and Class II appliances.
    • Clear PASS/FAIL indication on a large, backlit display.
    • Battery-operated for true portability and convenience on-site.
    • Lead null function for highly accurate Earth Bond test results.
    • Measures Insulation Resistance, Earth Bond Continuity, and Polarity.
    • Lightweight and robust design for demanding field use.
    • Automatic discharge of residual voltage for enhanced user safety.

     

    The KYORITSU 6205 Portable Appliance Tester is suitable for performing tests as required by the following standards – AS/NZS 3760 In-service safety inspection and testing of electrical equipment.

    Kyoritsu 6205 StatusKyoritsu 6205 Connector

    Kyoritsu 6205 Accessories

    Weight 1 kg

     

    KYORITSU 6205 Portable Appliance Tester Specifications:

    Test Function

    Function Tests of contents
    Class Ⅰ Test • Protective conductor resistance
    (Test current 200mA DC nominal)
    • Insulation resistance test (250V or 500V)
    • Leakage current test (100-253V/50Hz)
    • Load current test (100-253V/50Hz)
    Class Ⅱ Test • Insulation resistance test (250V or 500V)
    • Leakage current test (100-253V/50Hz)
    • Load current test (100-253V/50Hz)
    Extension Lead Test • Protective conductor resistance
    (Test current 200mA DC nominal)
    • Insulation resistance test
    (between Line/Neutral-Earth short, Line/Neutral)
    • Leakage current test (100-253V/50Hz)
    • Polarity test
    RCD Test • RCD test (10mA/30mA)

    Mains voltage indlcation

    Display range 30V-270V
    Accuracy ±5V

    Protective conductor resistance test

    Measuring range 0.00-20.00Ω
    Open circuit voltage 5V±0.4V DC
    Measuring current 200mA DC(nominal value)
    Accuracy ±3%rdg±5dgt

    Insulation resistance test

    Rated volatge 250V 500V
    Measuring range 0.00-20.00MΩ
    No-load voltage 250V DC +20%,-0% 500V DC +20%,-0%
    Short circuit current 1.5mA DC or less
    Accuracy ±2%rdg±3dgt

    Load current/Leakage current test

    Item Load current Leakage current
    Mains voltage range 100-253V/50Hz
    Measuring range 0.10-10.00A rms 0.10-20.00mA rms
    Accuracy ±10%rdg±5dgt ±3%rdg±5dgt

    RCD test

    Rated voltage 230V -15% – +10%/50Hz
    Rated current 10mA/30mA
    Function × 1 × 5
    Test duration 0.0ms-500.0ms 0.0ms-40.0ms
    Operating time accuracy ±2ms(≦40ms),±8ms(>40ms)

    General

    Power source LR6(AA)(1.5V) × 6
    Applicable Standards IEC/EN61010-1 CAT II 300V, IEC/EN61010-2-030,
    IEC/EN61010-031, EN61326-2-2, AS/NZ3760
    Dimentions / Weight 261(L) × 104(W) × 57(D)mm / Approx. 930g(including batteries)
    Included Accessories 7277(Mains lead),
    7129A(Test lead with Alligator clip),
    7161A(Flat test prod),
    7276(Adaptor for Extension cord),
    9193(Carrying case),
    8928(Fuse[10A/250V]),
    9121(Shoulder strap),
    Buckle, LR6(AA) x 6, Instruction manual
    Optional Accessories 8263-USB(USB cable with “KEW Report(software)”),
    7275(Printer cable:Mini Din 6pin-D-sub 9pin),
    7248(Test lead with Alligator clip and Flat test probe)

    FAQ Section:

    1. What types of appliances can the Kyoritsu KEW 6205 test?
      The KEW 6205 is designed to test Class I (earthed) and Class II (double insulated) electrical appliances, as well as extension leads and power cords.
    2. Is this device suitable for high-volume testing environments?
      Yes, its pre-programmed test sequences and clear pass/fail results make it highly efficient for professionals who need to test a large number of appliances quickly and accurately.
    3. Does the KEW 6205 require mains power to operate?
      No, the Kyoritsu KEW 6205 is fully battery-operated, offering complete portability for testing anywhere without reliance on a power outlet.
    4. How does the tester ensure measurement accuracy?
      It features a built-in “lead null” function that allows you to zero out the resistance of the test leads before performing an Earth Bond test, ensuring precise measurements.
    5. Is the Kyoritsu KEW 6205 compliant with UK safety standards?
      Yes, the device is designed to meet the requirements of relevant safety standards, including BS EN 61010-1 and BS EN 61557, making it suitable for professional use in the UK.