    Measures Carbon Dioxide (CO2)

    This Portable Indoor Air Quality CO2 Meter measures Carbon Dioxide (C02), Temperature, Humidity, Dew Point, and Wet Bulb. Checks for Carbon Dioxide (CO2) concentrations and calculates statistical weighted averages of TWA (8 hour time weighted average) and STEL (15 minute short term exposure limit). User programmable audible alarm. Data acquisition software and cable included to record and document CO2, Humidity and Temperature data. Complete with software and cable, 4 AA batteries, and carrying case.

    PDF Logo    CO250 datasheet
    PDF Logo    CO250_User Manual

    SKU: CO250 Categories: , , Tag:
    Extech CO250 Portable Indoor Air Quality CO2 Features:
    • Checks for Carbon Dioxide (CO2) concentrations
    • Calculates statistical weighted averages of TWA (8 hour time weighted average) and STEL (15 minute short term exposure limit)
    • Maintenance free NDIR (non-dispersive infrared) CO2 sensor
    CO2 Guidelines:
    Non-Enforced Reference levels:
    • 250 – 350 ppm – background (normal) outdoor air level
    • 350- 1,000 ppm – typical level found in occupied spaces with good air
    • 1,000 – 2,000 ppm – level associated with complaints of drowsiness and poor
    • 2,000 – 5,000 ppm – level associated with headaches, sleepiness, and stagnant, stale, stuffy air. Poor concentration, loss of attention, increased heart rate and slight nausea may also be
    • >5,000 ppm – Exposure may lead to serious oxygen deprivation resulting in permanent brain damage, coma and even

    Regulatory exposure limits:

    ASHRAE Standard 62-1989: 1000ppm: CO2 concentration in occupied building should not exceed 1000ppm.

    OSHA: 5000ppm: Time weighted average over five 8-hour work days should not exceed 5000ppm

    Building bulletin 101 (Bb101): 1500ppm. UK standards for schools say that CO2 at averaged over the whole day(i.e. 9am to 3.30 pm) should not exceed 1500ppm.

    Germany, Japan, Australia, UK…: 5000ppm, 8 hours weighted average in occupational exposure limit is 5000ppm.

    Extech CO250 Specifictions:

    Function Range Resolution Accuracy
     CO2 0 to 5000ppm 1ppm ±(%5rdg + 50ppm)
    5000 to 9999ppm 1ppm Not specified
    Pressure dependence: +1.6% reading per kPa deviation from normal pressure, 100kPa
    Temperature -10 to 60°C14 to 140°F 0.1° ±0.6°C/0.9°F
    Humidity 0.0 to 99.9% 0.1% ±3%(10 to 90%)±5%(< or > 10 to 90%)
    Wet Bulb -5 to 60°C23 to 140°F 0.1°  Calculated from RH and Temperature
    Dew Point -20 to 60°C-4 to 140°F 0.1°

     Display                   Triple LCD with backlight

    Sensor Type                   

    • CO2: NDIR (non-dispersive infrared) technology
    • Humidity: Capacitance sensor; Temperature (air): Thermistor

    Operating Conditions    0 to 50C (32 to 122F); < 95% RH non-condensing

    Storage Conditions    -20 to 60C ( -4 to 140F); <99% RH non-condensing

    Power Supply    4 x 1.5V ‘AA’ batteries or AC adaptor (9V/1A)

    Battery Life approx. 24 hours (alkaline batteries)

    Dimensions / Weight      200 x 70 x 57mm / 190g

    Reviews

    There are no reviews yet

    Be the first to review “Extech CO250 Portable Indoor Air Quality CO2 Meter”

    Need help? Call our support team 1800 358 531

    announcement  EOFY specials It's that time of the year again - the end of financial year! And here at MyMeter.

    PLUS,  Enjoy a 5% site-wide discount on all products when your cart total exceeds $1000.