The MyMeter Special Kit: Megger MFT-X1-EV Multifunction Installation Tester with EV Adaptor is the ultimate value pack for electrical professionals. This portable, user-friendly tool is perfect for accurate testing of low voltage installations, including EV charge points and photovoltaic systems. With its patented Confidence Meter™, colour display, and upgradeable software, it simplifies compliance while boosting efficiency. Get everything you need in one incredible kit—exclusively from MyMeter!
The Megger MFT-X1-EV Multifunction Installation Tester is your go-to solution for testing low voltage electrical installations. Specially designed for the installation, maintenance, and fault diagnostics of low voltage setups—including Electric Vehicle (EV) charge points and domestic photovoltaic (PV) systems—this tester encompasses everything you need in a single, portable device.
Megger Confidence Meter Technology: Faster and More Accurate Loop Testing
The Megger Confidence Meter technology revolutionises loop impedance testing by delivering faster, more reliable results. Supporting all loop impedance ranges, this patented technology significantly reduces test times for non-trip loop testing—down to just 7 seconds on quiet circuits. It also optimises testing in noisy electrical supplies, ensuring accurate and stable results.
The Confidence Meter actively monitors test progress and detects noise on the circuit, eliminating erroneous readings and providing consistent results every time.
Easily Download and Manage Results with the MFT-X1 and CertSuite
With the MFT-X1, installation test results can be tagged with circuit data and seamlessly transferred for efficient record-keeping. Combined with the CertSuite software, managing and certifying your test results has never been easier.
Whether you need faster testing, accurate measurements, or simplified report management, Megger tools are designed to enhance your electrical testing workflow.
Investing in the Megger MFT-X1-EV Multifunction Installation Tester means equipping yourself with a top-tier tool crafted by a leader in the electrical testing industry. The combination of accuracy, ease of use, and integration of EV and PV testing capabilities places this instrument ahead of competitors. Suitable for both seasoned professionals and newcomers, the MFT-X1-EV is designed to meet the evolving needs of the electrical industry.
In summary, the Megger MFT-X1-EV isn’t just another tester; it’s an all-in-one solution that combines functionality, safety, and convenience. Elevate your testing capabilities and ensure compliance with high standards by choosing the Megger MFT-X1-EV Multifunction Installation Tester today.
Weight | .5 kg |
---|
FUNCTIONAL SUMMARY
Voltage measurement |
|
Voltage range |
0.001 V to 2 V (mV range) 2 V to 600 V (V range), 1000 V DC (Non-CAT rated circuits) |
Voltage type: |
Trms, AC, DC |
Phase sequence |
Automatic phase sequence testing on detection of valid three phase supplies |
Current measurement (non-contact) |
|
AC Trms |
Using optional accessories: MCC1010 current clamp |
Measurement Range |
MCC1010: 1 mA to 300 A |
Continuity/Resistance |
|
Measurement range Digital display |
0.01 Ω to 999 kΩ Auto-ranging |
Measurement Range Analogue arc |
0 Ω to 1 MΩ log scale |
Test voltage |
4 V DC to 5 V DC |
Test current (Nominal) |
>200 mA 0 Ω >< 2 Ω 10 mA Auto reduction on high resistance (actual current reported in display) |
Test polarities |
Forward polarity |
Buzzer resistance range |
> 0.01 Ω < 2 kΩ |
Buzzer threshold |
0.3, 0.5, 1, 2, 3, 4, 5, 10, 20, 30, 40, 50, 100, 200 Ω |
Insulation testing |
|
Measurement range Digital display |
0.001 MΩ to 999 MΩ Auto-ranging |
Measurement range Analogue arc |
0.001 MΩ to >1000 MΩ log scale |
Insulation test voltages |
50 V DC to 1000 V DC + Variable 50 V to 999 V |
Test current |
1 mA to 2 mA |
Stabilised output voltage |
Output test voltage stabilised to -0% +2% +2 V |
True Loop™ loop impedance testing |
|
2 Wire – all modes |
|
Test types |
Mode 1: Non-Trip |
Mode 2: High current |
|
Mode 3: High resolution |
|
Resolution |
Non-Trip: 0.01 Ω |
High current: 0.01 Ω |
|
High resolution: 0.001 Ω |
|
Voltage range |
Non-trip: 48 V AC to 280 V AC |
High current: 48 V AC to 550V AC |
|
High resolution: 48 V AC to 550 V AC |
|
Frequency range |
45 Hz to 65 Hz (all modes) |
3 Phase testing |
Non-trip: Single phase only |
High current: Three phase |
|
High resolution: Three phase |
|
3 wire – non-trip |
|
Test types |
RCD (non-trip) RCD EV (non-trip on 6mA EV RDCs) |
Resolution |
0.01 Ω |
Voltage range |
48 V AC to 280 V |
Frequency range |
45 Hz to 65 Hz |
3 Phase testing |
Single phase only |
Volt drop |
|
Volt drop calculation |
Requires Zref (Ze) and circuit current (I-vdrop) |
Accuracy |
Dependent on loop impedance accuracy |
RCD testing |
|
RCD types supported |
Type AC, A, B, AC(S), A(S), B(S) |
Auto RCD sequence |
1 / 2x I∆n, 1x I∆n, 2x I∆n, 5x I∆n, Ramp, 0º / 180º (customer configurable) |
Ramp testing |
10 mA to 1000 mA |
RDC testing |
6 mA RDC |
Fault (Touch) voltage |
0 V to 253 V |
Earth testing |
|
2 wire |
2 wire earth resistance test |
3 wire |
3 wire earth resistance |
3 wire ART |
3 wire testing with additional MCC1010 current clamp |
Stakeless |
Stakeless testing using the MCC1010 and MVC1010 clamps |
SPECIFICATIONS
Voltage measurement
Function |
Range |
Accuracy |
Voltage DC |
0 V – ±1000 V |
±1% ± 3 digits |
Voltage AC/TRMS |
0 V – 600 V (15 – 500 Hz) |
±2% ± 1 digits |
Frequency |
15 Hz – 99 Hz 100 Hz – 500 Hz |
±0.5% ± 2 digit ±2.0% ± 2 digit |
Millivolt measurement
Function |
Range |
Accuracy |
mV AC/TRMS |
0 mV to 1999 mV (50 / 60 Hz) |
±1% ± 3 digits |
mV DC |
0 mV to ±1999 mV |
±1% ± 3 digits |
Live Earth detection
Indicates if the PE terminal is live when selecting the Loop or RCD test ranges. The relevant Loop or RCD test is inhibited.
Current
Function |
Range |
Accuracy |
Current AC/TRMS |
0.001 A – 0.100 A |
±2% ±3 digits |
0.100 A – 2.000 A |
±2% ±3 digits |
|
2.00 A – 20.00 A |
±2% ±3 digits |
|
20.0 A – 300.0 A |
±2% ±3 digits |
|
Frequency Bandwidth |
15 Hz – 500 Hz |
|
Influence of Frequency |
30 Hz – 500 Hz ≤0.25 % |
|
Resistance and Continuity
Function |
Range |
Test Current |
Accuracy |
200 mA |
0.01 Ω – 99.9 Ω |
(0 Ω – 2 Ω) 205 mA ±5 mA |
±3% ±2 digits |
10 mA |
0.01 Ω – 99.9 Ω |
10 mA |
±3% ±2 digits |
100 Ω – 999 kΩ |
±5% ±2 digits |
||
Open circuit voltage |
4 V to 5 V |
||
EN61557-4 Measurement Range: 0.10 Ω to 999 kΩ.
Safety and electrical protection
Safety rating: |
CAT III 600 V / CAT IV 300 V to EN 61010, IEC 61010-031 : 2015, IEC 61010-030. |
Safety category rating valid to altitude of 2000 m. |
Live voltage: |
Active live voltage protection to 600 V between any test terminals without blowing a fuse. Live voltage warning on display and audible when >5 V is applied between any test terminals. Fuse protected to 1000 V, fuses are not user changeable. |
Insulation test
Function |
Range |
Accuracy |
1000 V |
0.001 – 999 MΩ |
±3% ±2 digits |
500 V |
0.001 – 500 MΩ |
±3% ±2 digits |
> 500 MΩ |
±10% |
|
250 V |
0.001 – 250 MΩ |
±3% ±2 digits |
> 250 MΩ |
±10% |
|
100 V |
0.001 – 100 MΩ |
±3% ±2 digits |
> 100 MΩ |
±10% |
|
50 V |
0.001 – 50 MΩ |
±3% ±2 digits |
> 50 MΩ |
±10% |
|
VAR 50 V – 999 V |
Leakage current > 1 mA |
±3% ±2 digits |
Leakage current < 1 mA |
±10% |
|
Leakage current |
0.1 µA – 1.99 mA |
±10% |
Output voltage |
-0% +2% +2 V at rated load or less |
|
Voltage display |
±1% ± 3 V |
|
Short circuit current |
1.5 mA nominal |
|
Test current on load |
1 mA at min pass values of insulation |
|
Maximum capacitance |
2 µF for a stable reading, 5 µF absolute limit |
|
EN61557-2 Measurement Range: 0.10 MΩ to 999 MΩ.
Loop 2-Wire – No RCD (L-PE, L-N or L-L)
Function |
Range |
Accuracy |
2-Wire HR |
0.001 – 9.999 |
±2% ±0.030 Ω |
2-Wire |
0.01 Ω – 9.99 Ω |
±2% ±5 digits |
10.0 Ω – 99.9 Ω |
±10% ±5 digits |
|
100 Ω – 1999 Ω |
±10% ±5 digits |
|
Supply Voltage |
48 V – 550 V |
|
Supply Frequency |
45 Hz – 65 Hz |
|
Can be used to measure supply source resistance quickly and reliably between Line and PE or two Live conductors up to 550 V.
EN61557-3 Measurement Range: 0.30 Ω to 1999 Ω
Loop 2-Wire L-PE with RCD
Function |
Range |
Accuracy |
0.01 Ω – 1999 Ω |
±10% ±5 digits |
|
Supply Voltage |
48 V – 280 V |
|
Supply Frequency |
45 Hz – 65 Hz |
|
Note: Uses the Megger Confidence Meter to measure the supply source impedance of circuits protected with an RCD rated
≥30 mA when there are only two connections possible. When a neutral is available the three-wire test will provide a quicker, more accurate result.
Note: RCD may trip if there are high leakage currents in the circuit under test. This measurement is immune to the effect of inductance found in some RCDs as it measures resistance (RCD Uplift).
EN61557-3 Measurement Range: 1.00 Ω to 1999 Ω
Loop 3-Wire L-PE with RCD
Designation |
Test Current |
Application |
RCD |
15 mA |
For circuits protected by an RCD rated <= 30 mA |
RDC EV |
3 mA |
For EV charger circuits protected by a RDC and a Type A RCD rated <= 30 mA |
Function |
Range |
Accuracy |
0.01 Ω – 9.99 Ω |
±2% ±5 digits |
|
10.0 Ω – 199 9 Ω |
±10% ±5 digits |
|
Supply Voltage |
48 V – 280 V |
|
Supply Frequency |
45 Hz – 65 Hz |
|
Note: Uses the Megger Confidence Meter to measure the supply source impedance of circuits protected with an RCD when three connections are possible. The L-N Loop resistance needs to be less than 12 Ω. The resistances of the L-PE, L-N and N-PE loops
are all shown, and the accuracy of the L-PE resistance depends on the maximum resistance displayed. When the neutral is not available the two-wire test must be used.
Note: RCD may trip if there are high leakage currents in the circuit under test. This measurement is immune to the effect of inductance found in some RCDs as it measures resistance.
EN61557-3 Measurement Range: 1.00 Ω to 1999 Ω
RCD Tests Types A and AC
RCD Types |
AC, A, AC(S), A(S) |
RCD Rated Current (IΔn) |
10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 650 mA, 1000 mA, VAR |
½ I no-trip Test Current |
-10% – +0% 0.5 IΔn |
1 I, 2 I, 5 I trip test – AC current |
-0% – +10% M • IΔn |
1 I, 2 I, 5 I trip test – pulsed DC current |
-0% – +10% 1.4 • M • IΔn |
Trip time |
±10% |
Ramp trip test current |
±5% |
Fault Voltage (0 V – supply) |
+5% +15% ±0.5 V |
Supply Voltage |
48 V – 280 V |
Supply Frequency |
45 Hz – 65 Hz |
Type B
RCD Types |
B, B(S) |
RCD Rated Current (IΔn) |
10 mA, 30 mA, 100 mA, 300 mA, 500 mA |
½ I no-trip Test Current |
-10% – +0% (0.5 IΔn) |
1 I, 2 I, 5 I trip test Current |
-0% – +10% (2 IΔn) |
Trip time |
±10% |
Trip current (ramp) |
±5% |
Fault Voltage (0 V – supply) |
+5% +15% ±0.5 V |
Supply Voltage |
48 V – 280 V |
Supply Frequency |
45 Hz – 65 Hz |
RDC (Type EV) with a 30 mA Type A RCD
Test current |
2.0 mA increasing to 6.3 mA before being held at that current for 10s. |
Trip time |
±1% ±1 ms |
Trip current (ramp) |
± 5% |
Fault Voltage (0 V – supply) |
+5% +15% ±0.5 V |
Supply Voltage |
48 V – 280 V |
Supply Frequency |
45 Hz – 65 Hz |
Earth
Function |
Range |
Accuracy |
2-Wire test |
0.01 Ω – 1999 Ω |
±2% ±3 digits |
Test Frequency |
128 Hz |
|
Test Current |
4.5 mA |
|
Maximum auxiliary electrode resistance (3-wire test) |
5 kΩ |
|
Note: The 2-wire earth test measures resistance between the blue and green terminals using a 128 Hz square wave; the result includes the resistance of test leads.
EN61557-5 Measurement Range: 1 Ω to 1999 Ω.
Function |
Range |
Accuracy |
3 wire test |
0.01 Ω to 1999 Ω |
±2% ±3 digits |
Test frequency |
128 Hz |
|
Test current |
25 V, 4.5 mA |
|
Maximum auxiliary electrode resistance |
5 kΩ for 25V |
|
Function |
Range |
Accuracy |
3P ART |
0.01 Ω to 1999 Ω |
±5% ±3 digits |
Test frequency |
128 Hz |
|
Test current |
25 V, 4.5 mA |
|
Minimum test current through the clamp |
5 % |
|
Maximum auxiliary electrode resistance |
5 kΩ for 25V or 100 kΩ for 50 V |
|
EN 61557-5 Measurement Range: 1 Ω to 1999 Ω.
Function |
Range |
Accuracy |
Stakeless |
1.0 Ω to 60 Ω |
±7% ±5 digits |
Test frequency |
128 Hz |
|
EN 61557-5 Measurement Range: 1.00 Ω to 40.0 Ω.
Power supply
Li-ion rechargeable |
7.2 V DC 4400 mAh (non-serviceable) + charge status indication |
Battery charger (Li-ion) |
Input: 110 V / 230 V AC, 50/60Hz, 1.3 A Output: 3 A, 8.4 V DC |
Battery life (Li-ion) |
Li-ion: 4400 mAh = >15 hrs* Continuity: Approximately 2000 tests using Li-ion battery (0.5s test every 30s per EN 61557) Insulation: Approximately 1400 tests using Li-ion battery (0.5s test every 30s per EN 61557) Earth: Approximately 1600 tests using Li-ion battery *times based on typical daily test profile |
Battery charging time |
Li-ion: 2.5 to 3 hrs (ambient temperature dependent) |
LR6 (AA) battery module |
8 x LR6 (AA) Alkaline batteries |
Environmental
Conditions |
Range |
Operating Temperature |
-10 °C to +55 °C |
Storage Temperature |
-25 °C to +70 °C |
Operating Humidity |
90% R.H. at +40 °C max |
Ingress Protection |
IEC 60529: IP 54 : Equipment is protected against ingress of dust and water splashes and is suitable for indoor and outdoor use. |
Vibration |
MIL-PRF-28800F:class 2 |
Maximum operating altitude |
2000 m |
Pollution degree |
2 |
Mechanical
Length |
274 mm (10.79 ”) |
Width |
96 mm (3.78 ”) |
Depth |
143 mm (5.63 ”) |
Weight – Instrument only |
1.57 kg (3.46 Ib) |
Shipping weight |
5.6 kg (12.35 ib) |