    The Testo 310 basic flue gas analyser sets a new standard in affordable flue gas analysis with its rugged housing, simple design and advanced sensor technology.

    With five different fuels to select from, it provides the flexibility you need for your applications like checking furnace efficiency, boiler tuning, and water heater checks.

    Features:

    • Integrated measurement menus: Flue gas, draught, ambient CO & pressure

    • Bright backlit 2 line display and icons for easy viewing

    • Battery life up to 10 hours

    • 2 year warranty

        Testo 310 Datasheet

    The Testo 310 Flue Gas Analyzer. For reliable heating system checks

    The Testo 310 Flue Gas Analyzer is a fully featured residential combustion analyzer that provides exceptional value and complete capabilities in combustion testing and furnace efficiency. With its capability to perform both basic, or more complex flue gas analysis, maintenance or safety checks, or confirm furnace efficiency, the fully featured Testo 310 combustion analyzer delivers more combustion parameters.

    The stainless steel probe and cone-stop is perfect for residential, and boiler applications. The 310 can be used for accurate heating adjustments, so you can get it right the first time – every time.

    With five different fuels to select from (Natural Gas, Propane, Fuel Oil , Biomass 5%, Wood 20%), it provides the flexibility you need for your tuning opportunities. With an optional printer kit available, you are able to keep records of all readings taken.

    Testo 310 Applications:

    Draught measurement in the flue gas duct

    Draught measurement is actually a differential pressure measurement. This differential pressure occurs between two sub-areas as a result of a difference in temperature. This is turn generates a flow to compensate. In the case of flue gas systems, the difference in pressure is an indicator of the “chimney flue draught”. This is measured between the flue gas and ambient air at the measurement orifice at the core of the flue gas flow.

    To ensure the flue gases are safely transported through the chimney there must be a differential pressure (chimney flue draught) for boiler systems that work with low pressure.

    If the draught is permanently too high, the average flue gas temperature increases and therefore flue gas loss. The level of efficiency drops.

    If the draught is permanently too low, oxygen may be lacking during combustion, resulting in soot and carbon monoxide. This will also cause a drop in the level of efficiency.

    Ambient CO measurement in the heated environment

    Carbon monoxide (CO) is a colourless, odourless and taste-free gas, but also poisonous. It is produced during the incomplete combustion of substances containing carbon (oil, gas, and solid fuels, etc.). If CO manages to get into the bloodstream through the lungs, it combines with haemoglobin thus preventing oxygen from being transported in the blood; this in turn will result in death through suffocation. This is why it is necessary to regularly check CO emissions at the combustion points of heating systems, and places often frequented by people (in our case, where the combustion systems for hot water generation are), and in the surrounding areas.

    Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)

    The flue gas measurement for a heating system helps to establish the pollutants released with the flue gas (e.g. carbon monoxide CO) and the heating energy lost with the warm flue gas. In some countries, flue gas measurement is a legal requirement. It primarily has two objectives:

    1. Ensuring the atmosphere is contaminated as little as possible by pollutants; and

    2. energy is used as efficiently as possible.

    Stipulated pollutant quantities per flue gas volume and energy losses must never be exceeded.

    Measurement in terms of results required by law takes place during standard operation (every performance primarily using the appliance). Using a Lambda probe (single hole or multi-hole probe), the measurement is taken at the centre of flow in the connecting pipe (in the centre of the pipe cross-section, not at the edge) between the boiler and chimney/flue. The measured values are recorded by the flue gas analyzer and can be logged either for print out or transfer to a PC at a later stage.

    Measurement is taken by the installer at commissioning, and if necessary four weeks later by the flue gas inspector/chimney sweep, and then at regular intervals by the authorised service engineer.

    Measuring pressure on burners (nozzle pressure, gas flow pressure, etc.)

    Standard readings taken during services of domestic heating systems include checking the gas pressure on the burners. This involves measuring the gas flow pressure and gas resting pressure. The flow pressure, also called supplied pressure, refers to the gas pressure of the flowing gas and resting pressure of the static gas. If the flow pressure for gas boilers is slightly outside the 18 to 25 mbar range, adjustments must not be made and the boiler must not be put into operation. If put into operation nonetheless, the burner will not be able to function properly, and explosions will occur when setting the flame and ultimately malfunctions; the burner will therefore fail and the heating system will shut down.

    Testo 310 Specifications:

    Temperature – TC Type K (NiCr-Ni)
    Measuring range -20 to +100 °C
    Accuracy ±1 °C
    Resolution 0.1 °C
    Reaction time < 50 s
    Temperature (ambient temperature)
    Temperature – TC Type J (Fe-CuNi)
    Measuring range 0 to +400 °C
    Accuracy ±1 °C (0 to +100 °C)
    ±1.5 % of mv (> 100 °C)
    Resolution 0.1 °C
    Reaction time < 50 s
    Temperature (flue gas)
    Flue gas O₂
    Measuring range 0 to 21 Vol.%
    Accuracy ±0.2 Vol.%
    Resolution 0.1 Vol.%
    Reaction time t₉₀ 30 s
    Flue gas Draught
    Measuring range -20 to +20 hPa
    Accuracy ±0.03 hPa (-3.00 to +3.00 hPa)
    ±1.5 % of mv (Remaining Range)
    Resolution 0.01 hPa
    Flue gas degree of effectivity, Eta (calculated)
    Measuring range 0 to 120 %
    Resolution 0.10%
    Flue gas loss (calculated)
    Measuring range 0 to 99.9 %
    Resolution 0.10%
    Flue gas CO₂ calculation (calculated from O₂)
    Measuring range 0 to CO₂ max (Display range)
    Accuracy ±0.2 Vol.%
    Resolution 0.1 Vol.%
    Reaction time t₉₀ < 40 s
    Pressure measurement
    Measuring range -40 to +40 hPa
    Accuracy ±0.5 hPa
    Resolution 0.1 hPa
    Flue gas CO (without H₂-compensation)
    Measuring range 0 to 4000 ppm
    Accuracy ±20 ppm (0 to 400 ppm)
    ±5 % of mv (401 to 2000 ppm)
    ±10 % of mv (2001 to 4000 ppm)
    Resolution 1 ppm
    Reaction time t₉₀ 60 s
    Ambient CO
    Measuring range 0 to 4000 ppm
    Accuracy ±20 ppm (0 to 400 ppm)
    ±5 % of mv (401 to 2000 ppm)
    ±10 % of mv (2001 to 4000 ppm)
    Resolution 1 ppm
    Reaction time 60 s
    General technical data
    Dimensions 201 x 83 x 44 mm
    Operating temperature -5 to +45 °C
    Display type LCD
    Display function Backlit 2-line display
    Power supply Battery: 1500 mAh, mains unit 5V/1A
    Storage temperature -20 to +50 °C
    Weight (with probe) Approx. 700 g

    Testo 310 Flue Gas Analyser Standard Accessories

    • lithium battery
    • sensors
    • probe with cone
    • hose
    • silicon tubing (for pressure)
    • extra particulate filters (5),
    • AC power supply (USB)
    • calibration protocol certificate
    • case.

     

    Weight 1 kg

    Reviews

    There are no reviews yet.

    Be the first to review “Testo 310 Flue Gas Analyzer”

    Need help? Call our support team 1800 358 531

    • Place The Order and Earn Points Earn 100 Points on every AUD $10.00 spent
    • Write Review
      Write review and earn 300 Point
    • image
      Apply Points on Cart Total

      Conversion Rule: AUD $10.00 = 500 Point

    Check your point total now Check your point total now