    Kyoritsu 5410 tests the operation, tripping time and current of RCD’s without a Neutral connection. (2 wire testing)

      Kyoritsu 5410 Datasheet          Kyoritsu 5410 User Manual

    SKU: Kyoritsu-5410 Categories: , Tags: , , Brand:

    An RCD is a protective device used to automatically disconnect the electrical supply when an imbalance is detected between live conductors. In the case of a single-phase circuit, the device monitors the difference in currents between the active and neutral conductors.

    In a healthy circuit, where there is no fault current flowing to earth or protective conductor current, the sum of the currents in the line and neutral conductors is zero. If a line-to-earth fault develops, a portion of the line conductor current will, therefore, not return through the neutral conductor.

    The RCD monitors this difference, operates and disconnects the circuit when the residual current reaches a preset limit, the “residual operating current”. This is what the Kyoritsu 5410 tests.

    Key Features

    • Test RCD’s without Neutral connection (2 wire testing)
    • Measurement of RCD trip time
      Conducting testing of rated residual non-operating currents at
      × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
    • Measurement of trip out current
      Measuring trip out current by varying current automatically.
    • Remote Test
      Enabling a user to hold the Test Leads with his both hands
      by locking the Test Button. Measurement will automatically
      start when the main voltage is detected.
    • Voltage Measurement
      Carrying out a constant measurement of voltage in the
      stand-by mode at each Range.
    • Auto-detection of Contact voltage
      Detecting the voltage to earth of Earth electrodes or
      Protective conductors during RCD test – when applying
      test currents – at measurement using EARTH in order to
      prevent electrical shocks caused by the damaged earth.
      Measurement will be ceased at AC50V or more.
    • Dust- and Water-proof
      Dust- and Water-proof construction
      (designed to IEC 60529 IP54).
    • Backlight
      Facilitating working at dimly illuminated locations.

     