Owned and Operated by Australia's leading Test and Measurement Distributor
TEL: 1800-FLUKE-1 — 1800 358 531
$180.00 .( $198.00 inc. GST )
For all your equipment calibration needs, visit our MyCalibration website.
Free Delivery on orders over $1000
Shipping time may vary for certain products*
If you would like more information regarding this product, simply email us here.
HT38 is essential to identify the circuit breaker protecting a given socket on a panel board without having to dissect it.
HT38 includes a signal generator (HT38T) to be connected to the socket under test and a signal receiver (HT38R) capable of “exploring” all RCCBs of the panel board.
Q: Why getting HT38?
A: Because it permits to detect the RCCB of the line without having to dissect it. Q: Should the receiver be brought into contact with the RCCB’s terminals?
A: No, you just need to put the receiver HT38R on the RCCB’s casing to detect the signal generated by the transmitter HT38T
Q: Which is the maximum distance between a socket and the corresponding RCCB to be detected?
A: The maximum distance between HT38T (connected to the above said socket) and HT38R is 300m (on networks with rated voltage of 110V L , N) and is 500m (on networks with rated voltage of 230V L , N)
Q: According which principle does the instrument work?
A: The instrument works according to PLT principle. HT38T releases a signal into the cable under voltage which can be identified by the receiver HT38R.
Weight | 0.45 kg |
---|
General Specifications | |
Transmitter HT38T | |
Power supply | 110V / 230VAC, 50/60Hz |
Signal output current | <20mA |
External connection | integrated Schuko Europlug |
Distance from receiver | max 500m (1640ft) (230V mains supply) max 300m (984ft) (110V mains supply) |
Operating temperature | 0°C ÷ 40°C (32°F ÷ 104°F) |
Operating humidity | <80%RH |
Storage temperature | 0°C ÷ 50°C (32°F ÷ 122°F) |
Storage humidity | <95%RH |
Size (L x W x H) | 95 x 60 x 30mm (4 x 2 x 1in) |
Weight | 140g (5 ounces) |
Receiver HT38R | |
Power supply | 1x9V alkaline battery type IEC 6F22 |
Battery life | approx. 19 hours |
Auto Power OFF | after 3 minutes’ idling |
Operating temperature | 0°C ÷ 40°C (32°F ÷ 104°F) |
Operating humidity | <80%RH |
Storage temperature | 0°C ÷ 50°C (32°F ÷ 122°F) |
Storage humidity | <95%RH |
Size (L x W x H) | 195 x 60 x 35mm (8 x 2 x 1in) |
Weight | 130g (5 ounces) |
Mechanical protection | IP40 |
General specifications | |
Safety | IEC/EN61010-1 |
EMC | IEC/EN61326-1 |
Insulation | double insulation |
Pollution level | 2 |
Measurement category | CAT III 250V |
Max operating altitude | 2000m (6562ft) |
You must be logged in to post a review.