The faults that cost the most usually make the least noise
The failures that shut a site down rarely come out of nowhere. Insulation breaks down for months before a flashover. A bearing runs rough long before it seizes. A pneumatic system bleeds air every hour of every shift. The trouble is that the early warning signs are ultrasonic – far above the range of human hearing and buried under the noise of a working plant or a humming substation.
Traditionally, catching those signs has meant a different tool and a different specialist for each problem: a contact ultrasonic probe or dedicated PD equipment for electrical assets, vibration gear for rotating plant, and a separate leak detector for compressed air. Every inspection needs its own walk-round, its own close approach, its own report.
The Fluke ii1050 Acoustic Imager brings those inspections into one handheld tool. It shows you where the sound is coming from as a picture on screen, helps classify what it is, and lets you document and report the finding before you leave the asset.
How the ii1050 sees what you can’t hear
The ii1050 uses an array of 202 digital MEMS microphones to capture ultrasonic sound. By comparing tiny timing differences between microphones, it calculates where each sound originates. Fluke’s SoundSight™ technology then displays that as a coloured SoundMap™ overlay on a live image from the 13 MP visible-light camera – so you see the discharge on a particular insulator, or the leak on a particular fitting, rather than “somewhere over there”.
The ii1050 works across a 2 kHz to 100 kHz frequency band – the widest in the Fluke ii1030/ii1050 pair – with high-frequency acoustics support, user presets and manual band selection. That extra headroom at the top of the range is what lets the ii1050 address electrical and mechanical sources as well as leaks.
PDQ Mode™: partial discharge detection from a safe distance
Partial discharge (PD) is one of the earliest indicators that insulation in high-voltage equipment is degrading. Left alone, it can progress to tracking, flashover, unplanned outages and arc flash incidents.
PDQ Mode™ turns the ii1050 into a fast PD screening tool:
- Locates discharge sources visually on switchgear, transformers, insulators and overhead lines
- Estimates discharge probability using advanced, machine-learning-assisted algorithms to classify activity
- Displays a real-time PRPD (Phase Resolved Partial Discharge) pattern on the instrument, helping you judge the type of discharge and how seriously to treat it
Because it’s acoustic and non-contact, you scan energised equipment without opening panels or getting close to live parts. The ii1050 has a detection range of 0.5 m to more than 150 m (1.6 to more than 492 ft), depending on ambient conditions, so you can survey substation yards and overhead transmission and distribution lines from the ground while maintaining your site’s required safety clearances.
Typical PD applications include:
- Switchgear
- Transformers
- Insulators
- Substations
- Power distribution equipment
- Overhead transmission and distribution lines
Safety note: The ii1050 is a non-contact screening tool. Always follow your site’s electrical safety rules, approach distances and PPE requirements when inspecting energised equipment.
MecQ™: catch mechanical problems before you can feel them
Mechanical faults generate high-frequency acoustic signatures well before they show up as heat, vibration you can feel, or noise you can hear. MecQ™ Mode helps technicians identify early signs of:
- Bearing defects
- Friction (including lubrication issues)
- Turbulence
That makes the ii1050 a practical addition to condition monitoring on motors, pumps, fans, compressed-air-driven equipment and production machinery. Spot the developing problem on the walk-round, then schedule a closer look or a repair during a planned maintenance window instead of after a breakdown.
LeakQ™: compressed air, gas and vacuum leaks – quantified
The ii1050 includes the full leak detection toolset of the ii1030. LeakQ™ Mode estimates each leak’s:
- Size on a LeakQ™ scale (1–10)
- Rate (estimated volume)
- Cost
So you can rank repairs by financial impact and back up an energy-saving program with real numbers. The Fluke Online LeakQ™ Reporting Tool can also estimate the CO₂ emissions associated with identified compressed air leaks.
Beacon Mode for air-tightness
With the optional Fluke SB140 SoundBeacon™ ultrasonic transmitter, Beacon Mode reveals sealing defects in enclosed products, cabinets, vessels and assemblies. Place the beacon inside, scan the outside, and the escaping ultrasound shows exactly where the seal has failed – useful for QA on automotive assemblies, HVAC equipment, wind turbine components, pressure vessels and process piping.
Acoustic + thermal in one walk-round
Add the Fluke TC03A iSee™ Thermal Camera Attachment and the ii1050 combines acoustic, thermal and visible-light imaging in one workflow. Use thermal to confirm an acoustic finding, catch overheating connections and electrical hotspots, and capture a richer evidence pack in a single pass. The ii1050 supports combined PDQ + thermal and LeakQ + thermal reports on the device. The TC03A is available as an optional accessory or as part of an ii1050 thermal bundle – ask us about kit options.
Built for substations, plant rooms and outdoor work
- 1.2 kg with battery – easy to carry on long substation and plant surveys
- IP54 rated for dust and light rain
- 7-inch anti-glare, sunlight-readable touchscreen (1280 × 800) – clear in outdoor yards and bright switchrooms
- Built-in LED lighting for dark cabinets, basements and kiosks
- Two field-replaceable Li-ion batteries supplied – more than 7 hours total (2 × 3.5 h); internal USB-C charging in under 3 hours
- −10 to 45 °C operating temperature
- ¼”-20 tripod thread for steady long-range scans
- Array-health self-diagnostic that flags when the microphone array needs attention
Capture, tag, report – on the spot
The ii1050 is designed to cut the time between “found it” and “fixed it”:
- Blended visual + SoundMap™ photos (.JPG) and videos (.MP4, up to 5 minutes)
- Asset annotation – name, ID, type, leak type, gas type, pressure
- QR-code asset ID recognition for consistent tagging on route-based inspections
- Up to 4 photo notes per finding
- Inspection status – “As found”, “As left”, “Undetermined”
- Action requirement, priority and notes
- Operating conditions and weather notes
- On-device reporting for PDQ, LeakQ, PDQ + thermal, LeakQ + thermal and thermal modes
- Wi-Fi and 2 × USB-C for data transfer
- 128 GB storage (per datasheet) for large multi-asset surveys
Who should choose the ii1050
Choose the ii1050 when you need more than leak detection:
- Electrical asset owners and utilities screening switchgear, substations and overhead networks for PD
- Industrial electricians and HV technicians inspecting energised equipment
- Reliability and condition monitoring teams wanting early mechanical warnings
- Service providers and contractors offering combined PD, leak and mechanical surveys
- Maintenance teams who want one acoustic tool across the whole site
Industries include utilities, mining, oil and gas, process manufacturing (food and beverage, chemical, plastics, metals, pulp and paper) and large commercial facilities.
Only need leak detection? The Fluke ii1030 shares the 202-microphone array, 13 MP camera, LeakQ™ and Beacon Mode, with a 2–64 kHz band and >100 m range – without PDQ Mode™ or MecQ™.
Why buy from Rapid-Tech
Rapid-Tech specialises in test and measurement – we understand the difference between a leak survey and a PD inspection, and we’ll help you pick the right configuration: the ii1050 on its own, with the TC03A thermal attachment, or with the SB140 SoundBeacon™ added. Genuine Fluke equipment, Australian support and practical technical advice.
Request a quote and we’ll put together the right ii1050 package for your site.
Technical Specifications
| Specification | Fluke ii1050 | Why It Matters |
|---|---|---|
| Microphones | 202 digital MEMS | Finer localisation of faint and closely spaced sources |
| Frequency band | 2 kHz to 100 kHz | Wide band covers leaks, partial discharge and mechanical signatures |
| High-frequency acoustics | Yes | Supports electrical and mechanical inspections |
| Frequency selection | User presets or manual entry | Isolate the target from background noise |
| Detection range | 0.5 to >150 m (1.6 to >492 ft), depending on ambient conditions | Inspect energised assets and overhead lines from a distance |
| Acoustic field of view (typical) | 64° × 48° | Scan large areas quickly |
| Frame rate (nominal) | 25 FPS | Real-time SoundMap™ display |
| Measurement range (typical) | 20 kHz: −10.4 to 122 dB SPL; 25 kHz: −24.7 to 122 dB SPL; 31.5 kHz: −13 to 122 dB SPL; 40 kHz: −10.7 to 122 dB SPL; 50 kHz: 8 to 122 dB SPL | Detects very quiet sources without saturating on loud ones |
| Gain | Auto or user-selectable max dB | Fast scanning or fine control |
| PDQ Mode™ | Yes – discharge source ID, probability estimate, real-time PRPD | Screen and prioritise partial discharge in HV assets |
| MecQ™ | Yes – bearing defects, friction, turbulence | Early warning of mechanical wear |
| LeakQ™ | Leak size scale (1–10), rate and cost estimation | Prioritise leak repairs by cost |
| Beacon Mode | Yes, with Fluke SB140 SoundBeacon™ (optional) | Air-tightness and seal verification |
| Thermal | Yes, with Fluke TC03A (optional / bundle) | Combined acoustic + thermal evidence |
| Visible camera | 13 MP, 3× digital zoom, focus 50 cm to infinity | Clear images of the exact faulty component |
| Display | 7″ anti-glare LCD, sunlight readable, 1280 × 800, capacitive touch | Readable outdoors and in substations |
| Palettes | Grayscale, Ironbow, Blue-Red; overlay transparency 1–100 % | Adjust for scene and reporting |
| Image / video format | Blended visual + SoundMap™ .JPG / .MP4 (video up to 5 min) | Easy to share |
| Storage | 128 GB | Large surveys without offloading |
| On-device reporting | PDQ, LeakQ, PDQ + Ti, LeakQ + Ti, Ti mode | Reports done before you leave site |
| Asset ID | Text input and automatic QR-code identification | Route-based, repeatable inspections |
| Connectivity | 2 × USB-C, Wi-Fi | Quick transfer and charging |
| Battery | 2 × rechargeable, field-replaceable Li-ion; >7 h total (2 × 3.5 h) | Full-shift use with a battery swap |
| Charging | Internal via USB-C, <3 h | – |
| Lighting | Built-in LED | Dark cabinets and kiosks |
| Tripod mount | ¼”-20 UNC | Steady long-range scans |
| Operating temperature | −10 to 45 °C | Outdoor Australian conditions |
| Storage temperature | −20 to 70 °C | – |
| Relative humidity | 10 to 95 % RH, non-condensing | – |
| Operating altitude | Up to 2000 m | – |
| Ingress protection | IP54 | Dust and light rain |
| Dimensions (H × W × L) | 235 × 154 × 46 mm | Compact handheld |
| Weight (with battery) | 1.2 kg | Less fatigue on long surveys |
| Self-diagnostics | Microphone array-health test | Know when the array needs attention |
| Safety / EMC | IEC 61010-1 (pollution degree 2); IEC 61326-1; CISPR 11 Group 1 Class A; RoHS | – |
| Warranty | 2 years | – |
What’s in the box (standard ii1050)
- Fluke ii1050 Acoustic Imager
- 2 × lithium-ion smart battery packs
- Adjustable wrist strap and neck strap
- Hard carry case
- USB-C cable
- 65 W USB-C charger
Available configurations
- FLK-II1050 – ii1050 Acoustic Imager (standard kit above)
- FLK-II1050/T50HZ – ii1050 + TC03A thermal attachment kit (with TP01 pistol/tripod)
- FLK-II1050/50HZ/SB140 – ii1050 + TC03A thermal kit + SB140 SoundBeacon™
Optional accessories
- Fluke TC03A iSee™ Thermal Camera Attachment
- Fluke SB140 SoundBeacon™
- Fluke TP01 pistol grip / tripod
- Spare RRC2040 battery pack
What is the Fluke ii1050 used for?
The Fluke ii1050 is a handheld acoustic imager that detects partial discharge in high-voltage equipment, early mechanical faults such as bearing defects, and compressed air, gas and vacuum leaks. It shows ultrasonic sound as a colour map over a 13 MP camera image and can generate inspection reports on the device.
Can the Fluke ii1050 detect partial discharge?
Yes. The ii1050’s PDQ Mode™ locates partial discharge sources, estimates discharge probability and displays a real-time PRPD (Phase Resolved Partial Discharge) pattern, helping technicians assess insulation problems in switchgear, transformers, insulators, substations and overhead lines.
How far can the Fluke ii1050 detect from?
The ii1050 has a detection range of 0.5 m to more than 150 m (1.6 to more than 492 ft), depending on ambient conditions. This allows energised equipment and overhead lines to be screened from a safe distance.
What is MecQ™ on the Fluke ii1050?
MecQ™ is the ii1050’s mechanical inspection mode. It helps identify early high-frequency signs of bearing defects, friction and turbulence in motors, pumps, fans and other rotating or pneumatic equipment, before the problem can be felt or heard.
What is a PRPD pattern?
A PRPD (Phase Resolved Partial Discharge) pattern plots discharge activity against the phase angle of the AC voltage. The shape of the pattern helps technicians identify the type of discharge – such as surface, corona or internal discharge – and decide how urgently to act.
What’s the difference between the Fluke ii1050 and ii1030?
Both share a 202-microphone array, 13 MP camera, 7″ anti-glare display, LeakQ™ and Beacon Mode. The ii1050 adds PDQ Mode™ for partial discharge and MecQ™ for mechanical faults, a wider 2–100 kHz band (vs 2–64 kHz) and longer range of more than 150 m (vs more than 100 m), depending on ambient conditions.
Frequently Asked Questions
Is the Fluke ii1050 safe to use on energised equipment? The ii1050 is non-contact and can detect from more than 150 m away depending on ambient conditions, so you don’t need to approach or open live equipment to screen it. Always follow your site’s electrical safety procedures, approach distances and PPE requirements.
Can the ii1050 replace a dedicated partial discharge test set? The ii1050 is a fast acoustic screening and classification tool for airborne PD activity. For detailed diagnostics on specific assets, it’s commonly used alongside other PD measurement methods. Talk to us about your application.
Does the ii1050 do everything the ii1030 does? Yes. The ii1050 includes all of the ii1030’s leak detection capabilities, including LeakQ™ and Beacon Mode, and adds PDQ Mode™, MecQ™, a wider frequency band and longer detection range.
Can I add thermal imaging to the ii1050? Yes. The Fluke TC03A iSee™ Thermal Camera Attachment is available as an accessory or in an ii1050 thermal kit. The ii1050 can then produce combined PDQ + thermal and LeakQ + thermal reports on the device.
How long does the battery last? Two field-replaceable Li-ion batteries are supplied, providing more than 7 hours of use (2 × 3.5 hours). Charging is internal via USB-C and takes under 3 hours.
Is the ii1050 suitable for outdoor substation work? Yes. It’s IP54 rated, operates from −10 to 45 °C, has a sunlight-readable anti-glare display and built-in LED lighting.
How much does the ii1050 weigh? 1.2 kg including battery.
What warranty is included? A 2-year Fluke warranty.