The Fluke 17B MAX Digital Multimeter offers reliable performance with AC/DC measurements up to 1000V, CAT III 600V safety rating, resistance, capacitance, and diode testing. Its Input Alert™ alarm ensures safety, while the compact design, bright display, and fine test leads provide accurate measurements for DIYers and professionals alike.
The Fluke 17B MAX Digital Multimeter is the perfect tool for DIY enthusiasts, beginner electricians, and professionals in the electrical field. Offering robust functionality and a user-friendly design, it delivers accurate measurements while ensuring safety during operation. Whether you’re troubleshooting a circuit, testing electrical components, or working on electronics, the Fluke 17B MAX is the ultimate tool to have in your toolkit.
With a CAT III 600V safety rating and built-in overload protection, the Fluke 17B MAX ensures reliable performance while keeping you safe. It includes the innovative Input Alert™ Audible and Visual Alarm, which warns against incorrect test lead connections to prevent blown fuses and operational errors.
The multimeter features test leads with fine tips, making it ideal for circuit board testing and precise measurements. It’s the perfect companion for electricians and electronics R&D professionals.
The 17B MAX has a large, easy-to-read display with a bright backlight for working in dim environments. Its simple interface allows users to wake the meter from sleep mode by pressing any button, saving time and energy.
Includes diode testing to identify faulty diodes and an audible continuity tester for quick diagnostics. The 17B MAX is designed with a focus on both convenience and performance.
The Fluke 17B MAX continues the legacy of the 17B+ with significant improvements, making it one of the most reliable multimeters in its class. It is designed to meet the needs of electricians, technicians, and DIY hobbyists who demand accuracy and safety. With its Input Alert™ technology, incorrect connections are detected instantly, reducing the risk of errors and ensuring more productive workflows.
Switching to an incorrect function while the test leads are in the current terminals is a common mistake that can damage the multimeter. With Fluke’s Input Alert™ system, you’ll receive real-time audible and visual warnings that help protect the meter, prevent blown fuses, and reduce downtime.
Ready to enhance your electrical testing capabilities? The Fluke 17B MAX Digital Multimeter is your dependable partner for accurate measurements and safe operation. Buy now and experience the difference in performance and durability that Fluke is known for. Perfect for both professionals and beginners, the Fluke 17B MAX is built to handle every challenge with ease.
Weight | 1 kg |
---|
Specifications | ||||
---|---|---|---|---|
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]). | ||||
Function | Range | Resolution | Accuracy | |
15B MAX | 17B MAX | |||
AC Volts (40 Hz to 500 Hz)1 | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0 % + 3 | 1.0 % + 3 |
AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | 3.0 % + 3 |
DC Volts | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5 % + 3 | 0.5 % + 3 |
DC Millivolts | 600.0 mV | 0.1 mV | 1.0 % + 10 | 1.0 % + 10 |
AC Current μA (40 Hz to 400 Hz)2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
AC Current mA (40 Hz to 400 Hz)2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 | 1.5 % + 3 |
AC Current A (40 Hz to 400 Hz)2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | 1.5 % + 3 |
DC Current μA2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
DC Current mA2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 | 1.5 % + 3 |
DC Current A2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | 1.5 % + 3 |
Diode Test3 | 2.000 V | 0.001 V | 10% | 10% |
Temperature 4 | 50.0 °C to 400.0 °C 0 °C to 50.0 °C -55.0 °C to 0 °C |
0.1 °C | NA | 2 %+1 °C 2 °C 9 %+2 °C |
Resistance (Ohms)5 | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
Capacitance6 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 2000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
Frequency1 (10 Hz to 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
NA | 0.1 % + 3 |
Duty Cycle1 | 1% to 99% | 0.10% | NA | 1 % typical7 |
Continuity Threshold | — | — | 70Ω | 70Ω |
Backlight | — | — | Yes | Yes |
1 All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2 Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A 3Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA 4Use Type K thermocouple 5 Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA 6Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 7 Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %. |
Input Characteristics | ||||
---|---|---|---|---|
Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
AC Volts | 1000 V 1 | >10 MΩ, <100 pF | >60 dB at 50 Hz or 60 Hz | — |
AC Millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
DC Volts | 1000 V 1 | >10 MΩ, <100 pF | >100 dB at 50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz |
DC Millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
1106 V Hz max |
General Specifications | |
Maximum voltage between any Terminal and Earth Ground | 600 V |
Maximum differential voltage between V and COM terminals | 1000V |
Display (LCD) | 6000 counts, updates 3/sec |
Battery Type | 2 AA, IEC LR6 |
Battery life | 500 hours minimum |
Temperature | Operating 0 °C to 40 °C; Storage -30 °C to 60 °C |
Relative Humidity | Operating Humidity Non-condensing (<10 °C); ≤90 % RH at 10 °C to 30 °C; ≤75 % RH at 30 °C to 40 °C |
Operating Humidity, 40 MΩ range | ≤80 % RH at 10 °C to 30 °C; ≤70 % RH at 30 °C to 40 °C |
Altitude | Operating 2000 m; Storage 12000 m |
Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Fuse protection for current inputs | 440 mA, 1000 V, fast-blow, use only Fluke specified parts. 11 A, 1000 V, fast-blow, use only Fluke specified parts |
Size (HxWxL) | 183 mm x 91 mm x 49.5 mm |
Weight | 455 g |
Ingress Protection | IP40 |
Safety | IEC 61010-1, IEC61010-2-030: CAT III 600 V, Pollution Degree 2 |
Electromagnetic Environment | IEC 61326-1: Portable |
Electromagnetic Compatibility (EMC) | Only applicable in Korea |
Class A Equipment (Industrial Broadcasting & Communication Equipment)1
1Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.