Yokogawa CA450 Process Multimeter / Calibrator Functions:
Loop Check Functions
- Simultaneous 24 V loop power and mA measurement
- HART mode setting with loop power (250 OHM resistance)
Generation Functions
- SIMULATE (SINK) function simulates transmitters
- 4-20 mA span/step/auto-step/sweep output
Measurement Functions
- High accuracy signal measurement: DC mA 0.05%/30.000 mA
- Handheld DMM function
- Peak/Hold function for DCS power peak-to-peak measurement
- Dedicated sensor modes for direct reading of many sensor signal types
Enhanced Safety – Helps Eliminate Electric Shocks
- Current terminal shutter prevents incorrect connections
- Sensor function handles AC load current measurement
- Meets 600 V CAT. IV, 1000 V CAT. III safety standards
Linking with a PC
- Transfer data to a PC via IR-U
Yokogawa CA450 Process Multimeter Specifications:
| Specifications | Accuracy and Range |
| DC voltage | 0.09% rdg+1 dgt6 00.0 mV to 1000 V |
| Current voltage (true rms value) | 0.5% rdg+5 dgt 600.0 mV to 1000 V (45 to 500 Hz) |
| DC current (mA) | 0.05% rdg+2 dgt/30.000 mA |
| 0.05% rdg+2 dgt/100.00 mA | |
| Impedance | 0.2% rdg + 1 dgt 600.0Ω to 60.00 MΩ |
| Frequency | 0.005% rdg + 1 dgt199.99 Hz to 19.999 kHz |
| Diode test | 1% rdg + 2 dgt 2.000 V |
| Continuity | Beeps under 50 ±30Ω |
| Display update rate (times/sec.) | 2.5 to 5 |
| Data hold | |
| Peak hold (DCV) | |
| Standard deviation | |
| Max/min | |
| DC current (mA) | 0.05% to span of 20.000m A0.001mA to 25.000mA, Max. load 28 V |
| Simulate (Sink) | 0.05% to span of 20.000mA 0.001mA to 25.000mA, Ext. power 15 to 48 Vdc |
| Loop power function | 24V with 250Ω resistance ON/OFF function |
| Auto-step | |
| Auto-sweep | |
| Step (manual) | |
| Safety standard | EN61010/1000VCAT III, 600VCAT IV |
| Communication (optional) | IR-USB |
| Backlight | |
| Current terminal shutter prevents incorrect connections |