Its’s not by accident that the new series of HT60 series professional multimeters are so rugged and well spec’d as they are the result of research conducted with the most demanding users of this kind of equipment, namely laboratories, where the choice of a measuring instrument is subject to strict tests concerning precision, reliability and safety of measurements even in extreme conditions.
The HT Instruments new HT60 series is a complete range of professional CAT IV 600V multimeters, all able to measure in TRMS, autorange function is available on all models and with backlit display. The design is modern, but also ergonomic, to ensure maximum ease of use. They display with a high resolution, even in colour for the premium model HT64.
The new HT ITALIA HT64 professional multimeter is the result of an in depth research conducted with the most demanding users of this kind of equipment, namely laboratories, where the choice of a measuring instrument is subject to strict tests concerning precision, reliability and safety of measurements even in extreme conditions. Therefore the HT 60 series is a complete range multimeters, all able to measure in TRMS, all with CAT IV 600V Safety Rating, autorange function available on all models, with backlight display.
These features that make this range of professional instruments unique and invaluable.
Accuracy calculated as ±[%reading + (num dgt * resolution)] at 18°C ¸ 28°C, <75%HR
Range | Resolution | Accuracy | Input impedance | Overload protection |
600.0mV | 0.1mV | ±(0.1%rdg+5dgt) | 10MΩ | 1000VDC/ACrms |
6.000V | 0.001V | |||
60.00V | 0.01V | |||
600.0V | 0.1V | ±(0.2%rdg+5dgt) | ||
1000V | 1V |
Range | Resolution | Accuracy (*)50Hz ¸ 60Hz | Accuracy (*)61Hz ¸ 1kHz | Overload protection |
600.0mV | 0.1mV | ±(0.9%rdg+5dgt) | ±(3.0%rdg+5dgt) | 1000VDC/ACrms |
6.000V | 0.001V | |||
60.00V | 0.01V | |||
600.0V | 0.1V | |||
1000V | 1V |
(*) Accuracy specified from 5% to 100% of measurement range, Input impedance: >9MΩ,
Response time PEAK function: >1ms, Accuracy PEAK function: ±10%rdg
Range | Resolution | Accuracy (*)50Hz ¸ 1kHz | Input impedance | Overload protection |
6.000V | 0.001V | ±(3.0%rdg+20dgt) | >9MΩ | 1000VDC/ACrms |
60.00V | 0.01V | |||
600.0V | 0.1V | |||
1000V | 1V |
Range | Resolution | Accuracy | Overload protection |
600.0mA | 0.1mA | ±(0.9%rdg+5dgt) | Fast Fuse 0.8A/1kVAC/DC (inputs mA, mA) |
6000mA | 1mA | ||
60.00mA | 0.01mA | ||
600.0mA | 0.1mA | ±(0.9%rdg+8dgt) | |
10.00A | 0.01A | ±(1.5%rdg+8dgt) | Fast Fuse 10A/1kVAC/DC (input 10A) |
Range | Resolution | Accuracy (*)50Hz ¸ 1kHz | Overload protection |
600.0mA | 0.1mA | ±(1.2%rdg+5dgt) | Fast Fuse 0.8A/1kVAC/DC (inputs mA, mA) |
6000mA | 1mA | ||
60.00mA | 0.01mA | ||
600.0mA | 0.1mA | ||
10.00A | 0.01A | ±(1.5%rdg+5dgt) | Fast Fuse 10A/1kVAC/DC (input 10A) |
(*)Accuracy specified from 5% to 100% of measurement range
Response time PEAK function: >1ms, Accuracy PEAK function: ±10%rdg
AC+DC TRMS Current: accuracy (50Hz¸1kHz): ±(3.0%rdg + 20dgt)
Range | Resolution | Accuracy | Reading |
-25% ÷ 125% | 0.1% | ±50dgt | 0mA=-25%, 4mA=0%, 20mA=100%, 24mA=125% |
Range | Max test current | Open voltage | Overload protection |
<1.5mA | 3.2V | 1000VDC/ACrms |
Range | Resolution | Accuracy | Buzzer | Overload protection |
600.0Ω | 0.1Ω | ±(0.8%rdg+10dgt) | <50Ω | 1000VDC/ACrms |
6.000kΩ | 0.001kΩ | ±(0.8%rdg+5dgt) | ||
60.00kΩ | 0.01kΩ | |||
600.0kΩ | 0.1kΩ | |||
6.000MΩ | 0.001MΩ | |||
60.00MW | 0.01MΩ | ±(2.5%rdg+10dgt) |
Range | Resolution | Accuracy | Sensitivity | Overload protection |
60.00Hz | 0.01Hz | ±(0.09%rdg+5dgt) | 2Vrms min(20% < duty < 80%, <100kHz)
5Vrms min (20% < duty < 80%, >100kHz) |
1000VDC/ACrms |
600.0Hz | 0.1Hz | |||
6.000kHz | 0.001kHz | |||
60.00kHz | 0.01kHz | |||
600.0kHz | 0.1kHz | |||
1.000MHz | 0.001MHz |
Range | Resolution | Accuracy | Sensitivity | Overload protection |
40Hz ¸ 10kHz | 0.01Hz¸0.001kHz | ±(0.5%rdg) | 2Vrms | 1000VDC/ACrms |
Range | Resolution | Accuracy | Overload protection |
0.1 ¸ 99.9% | 0.01% | ±(1.2%rdg+2dgt) | 1000VDC/ACrms |
Pulse frequency range: 40Hz ¸ 10kHz, Pulse width: ±5V (100ms ¸ 100ms)
Range | Resolution | Accuracy | Overload protection |
60.00nF | 0.01nF | ±(1.5%rdg+20dgt) | 1000VDC/ACrms |
600.0nF | 0.1nF | ±(1.2%rdg+8dgt) | |
6.000mF | 0.001mF | ±(1.5%rdg+8dgt) | |
60.00mF | 0.01mF | ±(1.2%rdg+8dgt) | |
600.0mF | 0.1mF | ±(1.5%rdg+8dgt) | |
6.000mF | 0.001mF | ±(2.5%rdg+20dgt) |
Range | Resolution | Accuracy (*) | Overload protection |
-40.0°C ÷ 600.0°C | 0.1°C | ±(1.5%rdg+3°C) | 1000VDC/ACrms |
600°C ÷ 1350°C | 1°C | ||
-40.0°F ÷ 600.0°F | 0.1°F | ±(1.5%rdg+5.4°F) | |
600°F ÷ 2462°F | 1°F |
(*)Accuracy referred to instrument without probe
Display:
Weight | .5 kg |
---|