    Reed SD-230 pH meters are designed to accept any pH electrode with a BNC connector and are commonly used for measure pH and ORP levels in water.

     

    Authorised Australian Distributor.

     

    SKU: SD-230 Categories: , , , Tag:

    The SD-230 ORP and pH meter is a Reed real time datalogger with memory card slot. It features a large, easy-to-read LCD display and simple push-button operation. A powerful custom microprocessor LSI circuit and its last generation electronics allow the unit to provide features such as a pH range which is from 0 to 14.00pH. Reed SD-230 can measures and records the values of measurements for a later analysis with a computer. The gage has a good configurable sampling time, from 1 second to 3600 seconds and is compatible with any pH Electrode with a BNC connector. An easy to read LCD display with backlight shows the humidity and temperature simultaneously.

    REED SD-230 Features

    • Meter can select between ATC or manual temperature adjustment
    • Three Point Calibration
    • Accepts any pH Electrode with a BNC connector
    • Real time SD memory card datalogger with a built-in clock and
      calendar
    • Sampling time set from 1 second to 3600 seconds
    • Meter can switch to a Manual Datalogging
    • No extra software needed, just plug the SD card into the computer
      and it downloads directly to EXCEL
    • SD card capacity: 1 GB to 16 GB
    • Easy to read LCD with backlight
    • Auto power off or manual power off
    • Data hold, record max. and min. reading
    • High accuracy microcomputer circuit
    • Power by UM3/AA (1.5 V) x 6 batteries
    • USB/RS232 Computer interface

    REED SD-230 Specifications

    • Circuit: Custom microprocessor LSI circuit
    • Display: 52mm x 38mm LCD with backlight
    • Units: pH or ORP (mV)
    • pH Electrode: Any pH electrode with BNC connector (optional)
    • Input Impedance: 1012ohm
    • Temp. Compensation: Manual (1-100°C), ATC (0-65°C)
    • pH Range: 0-14pH
    • pH Resolution: 0.01pH
    • pH Accuracy: ±(0.02pH + 2d)
    • mV Range: 0-1999mV
    • mV Resolution: 1mV
    • mV Accuracy: ±(0.5% + 2d)
    • Auto Sampling Time: 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800,
      3600 seconds
    • Memory Card: SD memory card, 1 GB to 16 GB
    • Sampling Time: Approx. 1 second
    • Data Output: USB/RS232 PC computer interface
    • Operating Temperature: 0-50°C
    • Operating Humidity: Less than 85% R.H.
    • Power Supply: UM3/AA (1.5 V) x 6 batteries
    • Weight: 489g
    • Dimensions: 177 x 68 x 45mm
    • Optional accessories: 2G SD Card (SD-2GB)
      pH Electrode (PE-01, PE-03, PE-11)
      pH 7 Buffer Solution (PH-07)
      pH 4 Buffer Solution (PH-04)
      ATC Temperature Probe (TP-07)
      ORP Electrode (ORP-14)
      Soft Carrying Case (CA-05A)
      Tripod (BS-6)
      USB Cable (USB-01)
      RS232 Cable (UPCB-01)
      Data Acquisition Software (SW-U801-WIN)

     

    Weight 2 kg

    How to Use

    How to use Reed pH and ORP Meter (SD-230)

    Reed SA-230 works with ORP sensor to measure the oxidizing ability of chlorine in swimming pools pH Measurements (Manual Temp. Compensation)
    Turn on this data logger by pressing the Power Button and connect the Optional pH Electrode into the pH/BNC SD-230’s socket. Before taking measurements you need to Set the pH Manual Temperature Compensation value. Press and hold the SET Button for 2 seconds to enter the “Advanced Setting” mode. Press the Next Button scroll through eight main functions, shown on the lower display until the “t-Set” icon appear. When the lower display shows “t-SEt “, use the Up or Down Buttons to select the upper value to the desired Temperature Compensation value. The default value is 25°C (77°F). Press the Enter Button to save the setting as the default. Now you can exit “Advanced Settings” by pressing the Esc Button.
    Hold the Electrode Handle and let the Sensing head get fully immersed the measured solution. Shake the pH Electrode to let the probe’s internal air bubble drift out from the sensing head. The top display will show the pH value and the bottom display will show the setting for the Manual Temperature Compensation value.

    pH Measurements (ATC)
    For pH measurements you need to plug in the optional Temperature Probe into the Temperature Socket. Plug in the optional pH Electrode into the pH/BNC Socket. Immerse both the Temperature Probe and the pH Electrode into the measured solution. Shake the pH Electrode to let the probe’s internal air bubble drift out from the sensing head. The top display will show the pH value and the bottom display will show the measured Temperature.

    mV Measurements
    This instrument comes with an built in mV (millivolt) measurement function. This feature enables you to make ion-selective, ORP (oxidation-reduction potential), and other precise mV measurements. All of these measurements are easy to made and start when you will push down the “function button” so the unit switches from “pH” to “mV”. To return to pH measurements, press the Function Button again. Connect the optional ORP Electrode Plug into the pH/BNC Socket. 3) The Display will show the mV value.

    How to use Data hold and Data record functions
    You can hold on the measured values any time while taking a measurement by pressing the Hold Button once. Press the Hold Button once again will release the data hold function. To record the maximum and minimum pH or ORP readings, press the REC Button once, and a ”REC. MAX.” symbol along with the maximum value will appear on the display. Press the REC Button again, and a “REC. MIN.” symbol along with the minimum value will appear on the display.

    Reviews

    There are no reviews yet.

    Be the first to review “REED SD-230 REED pH and ORP Meter (data logger)”

    Need help? Call our support team 1800 358 531

    • Place The Order and Earn Points Earn 100 Points on every AUD $10.00 spent
    • Write Review
      Write review and earn 300 Point
    • image
      Apply Points on Cart Total

      Conversion Rule: AUD $10.00 = 500 Point

    Check your point total now Check your point total now