Modiewark AC Non-Contact Voltage Tester: Professional 110-750,000V Detector for Accurate and Safe Electrical Testing

$365.00$368.00


For all your equipment calibration needs, visit our MyCalibration website.


Free Delivery on orders over $1000
Shipping time may vary for certain products*

Product Enquiry

If you would like more information regarding this product, simply email us here.

  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.
    • This field is for validation purposes and should be left unchanged.

    Modiewark logo

    The Modiewark AC Non-Contact Voltage Tester offers precise detection from 110 to 750,000 volts, ideal for electricians and engineers seeking unmatched safety and performance in both overhead and underground environments. Trusted since the 1970s, it combines proximity and touch verification for reliable, user-friendly voltage testing in diverse applications.

    PDF Download Modiewark Product Brochure    PDF Download Modiewark Product Manual

    SKU: N/A Category: Tag:

    Buy the Original Modiewark AC Non-Contact Voltage Tester

    Included:

    • Modiewark AC non-contact voltage tester

    Discover the Ultimate Voltage Testing Solution

    The Modiewark AC Non-Contact Voltage Tester is an industry-leading device trusted by professionals for its accuracy, reliability, and safety in detecting voltage levels across various environments. Ideal for both contact and non-contact testing, this tool is a must-have for engineers, electricians, and safety inspectors dealing with AC electrical systems. Widely recognized since the 1960s, the Modiewark has set the international standard in non-contact voltage testing and remains an essential tool for maintenance, repairs, and emergency responses.

    Key Features of the Modiewark AC Non-Contact Voltage Tester

    • Voltage Detection Range: Detects AC electrical voltage from 110 volts to an impressive 750,000 volts.
    • Proximity Detection: Capable of identifying live or dead voltage situations from 200mm to 300mm away.
    • Touch Verification: Ensures accurate testing by reaching the AC field around designated mains.
    • Directional Checks: Unique sensor plate allows efficient checks even in complex voltage environments.
    • Versatile Usage: Compatible with a diverse range of AC power setups, making it perfect for any industry.

    Perfect for Diverse Applications

    The Modiewark AC tester is multi-functional, suitable for:

    • Identifying live conductors in various systems
    • Fault finding in flexible cables
    • Equipment grounding checks
    • Servicing and maintaining neon lighting
    • Tracking live wires and phasing conductors
    • Detecting high-frequency radiation

    Precision Meets Safety in Voltage Testing

    The Modiewark’s innovative design not only ensures the highest level of precision in identifying electrical currents but also enhances safety standards by reducing the need for direct contact with potentially high voltage systems. This device is especially valuable where induced voltages present a risk, allowing for safe and efficient field work.

    Optimal for Indoor and Outdoor Use

    Designed to operate across different environments, it serves industries relying on high voltage systems and also accommodates indoor settings like 240/110 volt systems. Whether mapping out voltage sources from distribution boards or pinpointing cable faults, the Modiewark AC Tester is versatile and dependable.

    Why Choose the Modiewark AC Non-Contact Voltage Tester?

    • Proven Reliability: Trusted by industry professionals since the early 1970s.
    • Unmatched Accuracy: Excellent for discerning live or dead situations and verifying voltage levels.
    • Exceptional Versatility: Adapts easily for both overhead and underground power line testing.
    • User-friendly: Easy to operate, minimizing downtime and enhancing productivity.

    With the Modiewark AC Non-Contact Voltage Tester, you get a device that blends historical reliability with cutting-edge performance. Ensure the safety and reliability of your testing operations with the Modiewark, the only tool you will ever need for all your voltage testing needs.

    Models Available:

    Explore our core models – SECV and MWB. Each is designed for specific transmission requirements and industry standards, providing solutions tailored to your precise testing environments.

    SECV OFF, 240V, 6.6kV, 11kV, 22kV, 66kV
    MWB OFF, 240V, 3.3kV, 6.6kV, 11kV, 22kV, 33kV

    Order yours now and experience superior voltage testing that industry professionals have trusted for over 50 years.

    Model

    SECV, MWB

    Features

    Case Configurations

    The Modiewark casing and handle are designed to channel a flashover around the internal circuit and into the battery housing. Please note any damage to the head of the Modiewark will result in failure the unit must be taken out of service and repaired.

    The Modiewark tester can now be fitted with moisture and dust proof fittings for harsh environments and provides an IP63 rating.

    Handles

    The standard Modiewark is supplied with a sunrise (universal) fitting to allow the attachment of an insulation extension stick (hot stick) for all high voltage applications. A standard or plain handle can be requested without this fitting.

    Self Testing Functions

    The Modiewark is available with and without a self test function. This continuous self checking of the Modiewark non-contact voltage tester provides an essential safety feature that:

    handle_plain
    Standard handle
    handle_sunrise
    Sunrise (Universal) Handle
    • Provides a circuit testA signal is generated within the unit and is passed to the sensor detection plate and then through the entire circuit, proving the circuit is active and in good working order.
    • Provides a test to prove that the visual and audio indicators are working correctly.
      The visual indicator is produced by three long life LEDs which provides the tester with two redundant light sources.Note: If audio or visual indicators are faulty take out of service and return for repair.
    • Battery Low Indicator.With a full battery charge of 4.5 volts the interval between the standby pulse is 1 second, as the battery power is lowered the pulse becomes further apart until it reaches 2.5 volts where the pulse becomes infrequent and stops. It is recommended to change the battery at a two second interval.

     

    Please note that all Australian models must be sold with the self test function.

    Battery Replacement

    The Modiewark uses 3 C size Alkaline, Lithium or rechargeable batteries.

    The batteries are placed in the handle with the positive side to the top. A battery strap is placed into the handle coil end first. When the batteries are placed in the handle shake to allow the battery strap to fall into the correct position.

    Screw the handle with batteries inside to the head unit, with a firm twist in a clock-wise direction.

    battery_handle_modiewark-e1381955753648

    Part Identification

    For further Modiewark features and models available please download the Modiewark products manual.

    Operation

    If using an insulation stick, place the unit onto the stick using the sunrise (universal) fitting or the bayonet adaptor fitting.

    If using handheld, hold the Modiewark unit by the handle below the sunrise fitting.

    1. Turn the unit on to the 240 volt switch setting (the first switch setting). This will allow for the most sensitive voltage detection.

    2. Listen and watch for the self testing function which will start automatically. If this does not occur there may be a few possibilities to consider before taking out of service:

    • Remove the handle and check that the batteries are placed in the correct way and the battery strap is in place. Shake the handle and screw into place.
    • If the pulses are 2 to 3 seconds apart or greater this indicates a low battery status and batteries will need to be replaced.
    • If the self test is still unresponsive, the unit may be faulty. Take out of service and return for repair.
    • If the unit is a non-self test model, tap the head of the Modiewark with a finger and listen for an activation tone in time with the tapping.
    modiewark-hand-isolated-306x281
    modiewark_sunrise_bayonet
    modiewark_usage_diagram

    3. To verify the tester using outside influences:

    • Place the tester against a live power outlet or equivalent above 110 volts AC.
    • Set the switch to 35kV overhead setting and place head of unit as marked against the spark plug of a running truck or car engine.
    • Use the Modielive tester to test the activation of the unit on the 240 volt setting.

    4. Hold the detection plate side to the power source under test. A continuous tone will be heard indicating live voltage.

    Underground Testing (URD)

    To test underground power in a residential or industrial environment, the procedure must be carried out with a unit designed for this purpose. Due to the depth and moisture content of the soil, testing for a cable underground is difficult.

    An accurate method of determining if URD connections are active is to test at a URD test point.

    1. Hold the unit in the hand by the handle below the sunrise fitting or for higher voltages an insulation stick or hot stick is recommended.

    2. Turn the unit on to the 240 volt switch setting (the first switch setting.) This will allow for the most sensitive voltage detection

    3. Listen and watch for the self testing function which will start automatically. If this does not occur there may be a few possibilities to consider before taking out of service:

    • Remove the handle and check that the batteries are placed in the correct way and the battery strap is in place. Shake the handle and screw into place.
    • If the pulses are 2 to 3 seconds apart or greater this indicates a low battery status and batteries will need to be replaced.
    • If the self test is still unresponsive, the unit may be faulty. Take out of service and return for repair.
    • If the unit is a non-self test model, tap the head of the Modiewark with a finger and listen for an activation tone in time with the tapping.

    4. To verify the tester using outside influences:

    • Place the tester against a live power outlet or equivalent above 110 volts AC.
    • Set the switch to 35kV overhead setting and place head of unit as marked against the spark plug of a running truck or car engine.
    • Use the Modielive tester to test the activation of the unit on the 240 volt setting.

    5. Hold the detection plate side to the URD test point elbow under test. A continuous tone will be heard indicating live voltage.

    Modiewark-URD-test-point

    6. If a tone is not heard at this point on the 240 volt setting move the tester closer to the conductor under test until the head of the tester is touching the conductor. At this point the voltage is below 50 volts AC. Please remember that voltages over 240 volts AC require personal protective equipment, gloves and hotsticks to increase the distance from the voltage source under test.

    7. If the tester activates metres away from the known source, this may not prove that the signal being picked up is from that source. Use the voltage range switch to determine the voltage required for the voltage test, by moving the switch settings higher as you approach the power source under test. The unit is designed to activate 100 to 200mm away from the voltage source if hand held.

    URD-test-points-horiz
    Examples of URD test point housings.

    Specifications

    Modiewark AC

    Voltage sending range 50V AC to 750kV AC
    Light source Three High Intensity LEDs
    Sound source Electromagnetic piezo 85 dB @ 5cm (1.9″)
    Operating temperature -40 to 65c (-40 to 149F)
    IP range IP 63
    Weight 900g (without batteries)
    Dimensions Length: 230mmWidth: 65.85mm (9″)
    Cap diameter 90mm (3.5″)

    Spout Tester

    Voltage setting range 3 x C size Alkaline
    Positive to handle thread
    Dimensions Length: 240mm + spout length
    Width: 65.85mm (9″)
    Cap diameter: 90mm (3.5″)
    Weight: 1.2kg (150mm spout)

    Batteries

    Battery type 50V AC to 33kV
    Battery life (standard C size Alkaline)
    ON (no alarm) 140+ Hours
    ON (Self test) 90 + Hours
    ON (alarm on) 60+ Hours
    OFF No current drawn, battery shelf life

    Reviews

    There are no reviews yet

    Be the first to review “Modiewark AC Non-Contact Voltage Tester: Professional 110-750,000V Detector for Accurate and Safe Electrical Testing”

    Need help? Call our support team 1800 358 531