HT Italia HT9015 AC/DC true rms Clamp meter 600A, 6000 points – CAT IV
HT9015 professional clamp is designed for DC/AC TRMS current measurement up to 600A, and DC/AC voltage for achieve safety CAT IV 1000V according to IEC/EN61010-1 safety standard.
HT9015 professional clamp is designed for DC/AC TRMS current measurement up to 600A, and DC/AC voltage for achieve safety CAT IV 1000V according to IEC/EN61010-1 safety standard.
The HT Italia HT9015 has a large LCD 4 digit display (6000 counts), with backlight and bargraph to more easy reading in critical environments. The model perform also resistance, continuity test, frequency, capacitance, diode test, duty cycle and temperature with type K probe measurements. The AutopowerOFF feature is also available for the meter in order to preserve it’s internal battery charge.
HT Italia HT 9015 Functions:
- TRMS measurement
- DC/AC current up to 600A
- DC/AC voltage up to 1000V
- “Voltsense” feature for AC voltage detection
- Resistance
- Continuity test with buzzer
- Frequency with jaws and test leads
- Capacitance
- Diode test
- Duty Cycle
- Temperature with type K probe
- Autorange
- Data HOLD
- MAX/MIN/ZERO
- PEAK CURRENT (<10ms)
- Backlight
- Bargraph
- Auto Power OFF
-
Instruments HT9015 Technical Specifications Accuracy is calculated as [% rdg + (number of dgt) x resolution]. It is referred to the following reference conditions: 18°C ÷ 28°C (65°F ÷ 83°F) with RH < 75% ELECTRICAL SPECIFICATIONS DC Voltage (Autorange) 600.0mV – 1000V AC Voltage TRMS (Autorange) 6.000V – 1000V Resistance and Continuity test (Autorange) 600.0Ω – 60.00MΩ DC Current 60.00A – 600.0A AC TRMS Current 60.00A – 600.0A Capacitance (Autorange) 40.00nF – 4000µF Frequency with test leads (Autorange) 99.99Hz – 60.00kHz Frequency with jaws (Autorange) 99.99Hz – 9.999kHz GENERAL SPECIFICATIONS Mechanical characteristics Dimensions (L x W x H) 215 x 74 x 43mm ; 8 x 3 x 2 in Weight (including battery) 285g (10 ounces) Max conductor size 30mm (1in) Supply Battery type 1 battery 9V NEDA 1604 IEC 6F22 JIS 006P Battery life about 200 hours. Auto power OFF after 15 minutes of idleness (not disabled) Display Characteristics 4 LCD (max 6000 counts), decimal point, unit symbol indication, bargraph and backlight Sample rate 2 times/sec Conversion mode TRMS Climatic conditions Reference temperature 18°C ÷ 28°C (65°F ÷ 83°F) Operating temperature 5 ÷ 40 °C (41°F ÷ 104°F) Operating humidity <80%RH Storage temperature -20 ÷ 60 °C (-4°F ÷ 140°F) Storage humidity <80%RH Reference Standards Comply with IEC/EN 61010-1 Insulation double insulation Pollution Level 2 For inside use, max height 2000m Installation category CAT IV 600V, CAT III 1000V to ground