Fluke 393 FC CAT III 1500 V -| True-rms Clamp Meter with iFlex

AUD $1,220.00 .( AUD $1,342.00 inc. GST )


For all your equipment calibration needs, visit our MyCalibration website.


Free Delivery on orders over $1000
Shipping time may vary for certain products*

Product Enquiry

If you would like more information regarding this product, simply email us here.

  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.
    • This field is for validation purposes and should be left unchanged.

    fluke logo

    This 393 FC is ideal for technicians who work in DC environments, such as solar farms, wind power turbines, electric railways, and data centers with battery banks that provide uninterruptible power.

    Key features:

    • Measure safely with CAT III 1500 V rated clamp meter
    • Thin jaw for access to cables in crowded combiner boxes
    • Sturdy IP54 rated for outdoor use
    • Ideal for use on Large Scale Solar farms and wind power systems
    • Work efficiently with dc power measurement, audio polarity and visual continuity

    PDF Datasheet  Fluke 393 FC Datasheet

    The Fluke 393 FC CAT 3 1500V True-RMS Clamp Meter with iFlex has many great features

    Fluke 393 FC CAT III 1500 V True-rms Clamp Meter in use

    Fluke 393 FC CAT III 1500 V True-rms Clamp Meter in use

    This 393 FC CAT III 1500 V True-RMS Clamp Meter with iFlex is ideal for technicians who work in DC environments, such as solar farms, wind power turbines, electric railways, and data centers with battery banks that provide uninterruptible power.

    With the True-RMS Clamp, you will be able to measure up to 1500 V DC, 1000 V AC, and 999.9 A DC and AC through the clamp jaw. iFlex flexible current probe enhances AC current measurements to 2500 amps. This clamp has a thin jaw, making it easy to access cables in crowded combiner boxes. Test leads are made to meet your needs, and are also rated to CAT III 1500 V DC.

    With the detachable iFlex (Flexible Current Probe), the measurement range is extended to 2500 A AC. The iFlex also provides increased display flexibility and allows measurements of odd-sized conductors and improved wire access.

    Other key functions:

    • IP54 rated, ideal for work outdoors on solar arrays and wind power systems
    • DC power measurement, showing readings in kVA
    • Audio Polarity indicator helps prevent accidental miswires
    • Visual Continuity turns provide a bright green light in the display, ideal when working in dark and noisy environments
    • Logging and reporting of test results via Fluke Connect software
    • When measuring ac current the included iFlex flexible current probe gives you unparalleled access to cable is tight spaces. The iFlex probe can be twisted through extremely small spaces and provide accurate current measurements.

    Fluke Connect™ (393 FC)

    The Clamp can be wirelessly connected to a mobile phone using the Fluke Connect™ software. The app shows the measurements and other data on your smartphone or tablet display. Fluke Connect Cloud allows you to share collected measurements and calculations with your team.
    Using Low-Power Wireless Radio Technology, Fluke Connect is able to connect your Clamp with an app on your smartphone or tablet. Clamp measurements aren’t affected by wireless radio interference.

    Weight 0.6 kg

    Specifications

    Fluke 393 FC CAT III 1500 V True-rms Clamp Meter with iFlex

    Specifications:
    General
    Maximum voltage between any Terminal and Earth Ground
    AC 1000 V
    DC 1500 V
    Batteries 2 AA IEC LR6 alkaline
    Display Dual display with backlight
    Automatic Power Off 20 minutes
    Electrical
    Accuracy
    Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
    Temperature Coefficients Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
    AC Current: Jaw
    Range 999.9 A
    Resolution 0.1 A
    Accuracy 2 % + 5 digits (10 Hz to 100 Hz)
    2.5 % + 5 digits (100 Hz to 500 Hz)
    Crest Factor (50/60 Hz) 2.5 @600.0 A
    3.0 @500.0 A
    1.42 @999.9 A
    Add 2 % for C.F. >2
    AC Current: Flexible Current Probe
    Range 999.9 A
    2500 A
    Resolution 0.1 A (≤999.9 A)
    1 A (≤2500 A)
    Accuracy 3 % RD + 5 digits (10 Hz to 500 Hz)
    Crest Factor (50/60Hz) 2.5 @1400 A
    3.0 @1100 A
    1.42@2500 A
    Add 2 % for C.F. >2
    Position Sensitivity
    iflex-specs
    Distance from Optimum i2500-10 Flex i2500-18 Flex Error
    A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 %
    B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 %
    C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 %
    Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
    DC Current
    Range 999.9 A
    Resolution 0.1 A
    Accuracy 2 % RD + 5 digits[1]
    [1] When using the ZERO (B) function to compensate for offsets.
    AC Voltage
    Range 600.0 V
    1000 V
    Resolution 0.1 V (≤600.0 V)
    1 V (≤1000 V)
    Accuracy 1 % RD + 5 digits (20 Hz to 500 Hz)
    DC Voltage
    Range 600.0 V
    1500 V
    Resolution 0.1 V (≤600.0 V)
    1 V (≤1500 V)
    Accuracy 1 % RD + 5 digits
    mV dc
    Range 500.0 mV
    Resolution 0.1 mV
    Accuracy 1 % RD + 5 digits
    Amps Frequency: Jaw
    Range 5.0 Hz to 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5 % RD + 5 digits
    Trigger Level 5 Hz to 10 Hz, ≥10 A
    10 Hz to 100 Hz, ≥5 A
    100 Hz to 500 Hz, ≥10 A
    Amps Frequency: Flexible Current Probe
    Range 5.0 Hz to 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5 % RD + 5 digits
    Trigger Level 5 Hz to 20 Hz, ≥25 A
    20 Hz to 100 Hz, ≥20 A
    100 Hz to 500 Hz, ≥25 A
    Voltage Frequency
    Range 5.0 Hz to 500.0 Hz
    Resolution 0.1 Hz
    Accuracy 0.5 % RD + 5 digits
    Trigger Level 5 Hz to 20 Hz, ≥5 V
    20 Hz to 100 Hz, ≥5 V
    100 Hz to 500 Hz, ≥10 V
    DC Power
    Range 600.0 kVA (600.0 V dc range)
    1500 kVA (1500 V dc range)
    Resolution 0.1 kVA
    1 kVA
    Accuracy 2 % RD + 2.0 kVA
    2 % RD + 20 kVA
    Resistance
    Range 600.0 Ω
    6000 Ω
    60.00 kΩ
    Resolution 0.1 Ω (≤600.0 Ω)
    1 Ω (≤6000 Ω)
    0.01 kΩ (≤60.00 kΩ)
    Accuracy 1 % RD + 5 digits
    Capacitance
    Range 100.0 μF
    1000 μF
    Resolution 0.1 μF (≤100.0 μF)
    1 μF (≤1000 μF)
    Accuracy 1 % RD + 5 digits
    Inrush Trigger Level 5 A
    Mechanical
    Size (L x W x H) 281 mm x 84 mm x 49 mm
    Weight (with batteries) 520 g
    Jaw Opening 34 mm
    Flexible Current Probe Diameter 7.5 mm
    Flexible Current Probe Cable Length
    (head to electronics connector) 1.8 m
    Environmental
    Operating Temperature -10 °C to 50 °C
    Storage Temperature -40 °C to 60 °C
    Operating Humidity Non condensing (<10°C)
    ≤90 % RH (at 10 °C to 30 °C)
    ≤75 % RH (at 30 °C to 40 °C)
    ≤45 % RH (at 40 °C to 50 °C)
    Operating Altitude 2000 m
    Storage Altitude 12 000 m
    Ingress Protection (IP) Rating IEC 60529: IP54 non-operating
    Electromagnetic Compatibility (EMC)
    International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
    Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
    Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
    Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
    Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
    Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
    USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
    Safety
    General IEC 61010-1, Pollution Degree 2
    Measurement IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
    IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
    Wireless Radio
    Radio frequency certification FCC ID: T68-FBLE, IC: 6627A-FBLE
    Wireless Radio Frequency Range 2400 MHz to 2483.5 MHz
    Output Power <100 mW
    SIMPLIFIED EU DECLARATION OF CONFORMITY
    Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
    The full text of the EU declaration is available at the following Internet address:
    www.fluke.com/en-us/declaration-of-conformity

    Reviews