Fluke 568 Features:
Measure -40 °C to 800 °C /-40 °F to 1472 °F
Easily access advanced features with the soft-key buttons and dot-matrix display
Compatibility with all standard miniconnector
Confidently measure a wide variety of surfaces, with the adjustable emissivity feature, including a built-in material table
Easily adapt to lighting conditions with 2 levels of backlight
Audible and visual alarms instantly alert you to measurements outside of your set limits
Quickly identify problems with the MIN, MAX, AVG, and DIF functions
Make contact thermometer measurements right away with the included Type-K thermocouple bead probe
Confidently troubleshoot equipment with 1 % measurement accuracy
Versatile interface with 6 languages from which to choose
Easily trend and analyze data with included FlukeView® Forms software
Quickly download stored data with USB connection
See your data right away without leaving the site, using the USB and your laptop
Extend your battery life by powering the digital thermometer from your laptop via the USB
Infrared temperature range | -40 C to 800 Degrees C |
Infrared accuracy | < 0 Degrees C (32 Degrees F): +/- (1.0 Degree C (+/- 2.0 Degrees F) + 0.1 Degree/1 Degree C or F); > 0 Degrees C (32 Degrees F): +/- 1 % or +/- 1.0 Degree C (+/- 2.0 Degrees F), whichever is greater |
Display resolution | 0.1 Degree C / 0.1 Degree F |
Infrared spectral response | 8 um to 14 um |
Infrared response time | < 500 msec |
Thermocouple Type-K input temperature range | -270 C to 1372 Degrees C |
Thermocouple Type-K input accuracy | -270 C to -40 Degrees C: +/- (1 C + 0.2 Degrees/1 Degree C) (-454 F to -40 Degrees F: +/- (2 Degrees F + 0.2 Degrees/1 Degree F)) -40°C to 137°C: 1 % or 1° (-40 °F to 2501°F: 1 % or 2°F), whichever is greater |
D:S (distance to measurement spot size) | 50:1 |
Laser sighting | Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm |
Minimum spot size | 19 mm (0.75 in) |
Emissivity adjustment | By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01 |
Data storage with Date/Time stamp | 99 points |
Hi/Low alarms | Audible and two-color visual |
Display | Dot matrix 98 x 96 pixels with function menus |
Power | 2 AA/LR6 Batteries and USB when used with a PC |
Battery life (If used continuously) | laser and backlight on,12 hours; laser and backlight off, 100 hours |
Operating temperature | 0 C to 50 Degrees C |
Storage temperature | -20 C to 60 Degrees C |
Bead thermocouple Type-K range | -40 C to 260 Degrees C |
Bead thermocouple Type-K accuracy | +/- 1.1 Degree C (2.0 Degrees F) from 0 C to 260 Degrees C (32 F to 500 Degrees F), typically within 1.1 Degree C (2.0 Degrees F) from -40 C to 0 Degrees C (-40 F to 32 Degrees F) |
PC Interface and cable | USB 2.0 with FlukeView Forms software |