Metrel MD 9260 -| TRMS Photovoltaic Clamp Meter CAT III 1500 V DC

$595.00 .( $654.50 inc. GST )


For all your equipment calibration needs, visit our MyCalibration website.


Free Delivery on orders over $1000
Shipping time may vary for certain products*

Product Enquiry

If you would like more information regarding this product, simply email us here.

  • Drop files here or
    Accepted file types: jpg, gif, png, pdf, Max. file size: 1 MB, Max. files: 4.
    • This field is for validation purposes and should be left unchanged.

    Metrel-Logo

    The Metrel MD 9260 TRMS Photovoltaic Clamp Meter is the perfect choice for anyone looking for a reliable and accurate measurement tool for their high-voltage projects. Its wide range of features and safety ratings make it an invaluable asset to have, ensuring that your measurements are safe and precise. With its easy setup and intuitive user interface, you’ll be able to get the most out of this instrument in no time. Take advantage of all the benefits this device has to offer while working confidently in hazardous environments with up to 1500 V DC!

    PDF download Metrel MD 9260 Datasheet

    SKU: MD-9260 Category: Tag:

    The Metrel MD 9260 TRMS Photovoltaic Clamp Meter is a rugged, high-performance device that allows safe measurements in hazardous environments with up to 1500 V DC. It’s the perfect tool for photovoltaic and wind plant testing, providing the accurate data you need with a range of capabilities such as TRMS AC and DC voltage/current measurement, capacitance measurement, resistance measurement, frequency measurement with VFD technology, diode test, temperature detection along with non-contact electrical field detection. This clamp meter also offers added protection from 12 kV transients and has CAT III 1500 V DC safety rating as well as CAT IV 1000 V safety rating. With its current range reaching 2000 A., this instrument truly is an all-inclusive professional measuring solution.

    Measuring functions

    • TRMS AC and DC voltage measurement;
    • TRMS AC and DC current measurement;
    • Capacitance measurement;
    • Resistance measurement;
    • Frequency measurement with VFD;
    • Diode test;
    • Temperature measurement;
    • Acoustic continuity;
    • Non-contact electrical field detection.

    Key features

    • 1500 V DC range with CAT III safety.
    • TRMS for accurate measurement of sine and non-sine signals.
    • VFD: low-pass filter for accurate frequency measurements of noisy signals.
    • High current range of 2000 A.
    • CAT III 1500 V DC and CAT IV 1000 V safety
    • Protection against 12 kV transients.
    • Auto and manual ranging.
    • Relative zero: easily compare consecutive measurements.
    • Crest function catches peaks as short as 5 ms.
    • Temperature measurements up to 1000 °C.
    • PC connection (optional): logging directly to a PC.

    Technical data

    • Dimensions (w x h x l): 264 x 97 x 43 mm
    • Mass (without accessories): 608 g
    Weight 1 kg

    Measuring functions

    • TRMS AC and DC voltage measurement;
    • TRMS AC and DC current measurement;
    • Capacitance measurement;
    • Resistance measurement;
    • Frequency measurement with VFD;
    • Diode test;
    • Temperature measurement;
    • Acoustic continuity;
    • Non-contact electrical field detection.

    Features

    • 1500 V DC range with CAT III safety.
    • TRMS for accurate measurement of sine and non-sine signals.
    • VFD: low-pass filter for accurate frequency measurements of noisy signals.
    • High current range of 2000 A.
    • CAT III 1500 V DC and CAT IV 1000 V safety
    • Protection against 12 kV transients.
    • Auto and manual ranging.
    • Relative zero: easily compare consecutive measurements.
    • Crest function catches peaks as short as 5 ms.
    • Temperature measurements up to 1000 °C.
    • PC connection (optional): logging directly to a PC.

    Standards applied

    Instrument safety towards user

    • IEC/EN 55022 Information technology equipment – Radio disturbance characteristics
    • IEC/EN 61000 Electromagnetic compatibility (EMC) series
    • IEC/EN 61000-3-2 Electromagnetic compatibility (EMC) – Part 3-2 – Limits – Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
    • IEC/EN 61000-3-3 Electromagnetic compatibility (EMC) – Part 3-3 – Limits – Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
    • IEC/EN 61000-4-2 Electromagnetic compatibility (EMC)- Part 4-2: Testing and measurement techniques – Electrostatic discharge immunity test
    • IEC/EN 61000-4-3 Electromagnetic compatibility (EMC)- Part 4-3: Testing and measurement techniques – Radiated, radio-frequency, electromagnetic field immunity test
    • IEC/EN 61000-4-4 Electromagnetic compatibility (EMC) – Part 4-4: Testing and measurement techniques – Electrical fast transient/burst immunity test
    • IEC/EN 61000-4-5 Electromagnetic compatibility (EMC) – Part 4-5: Testing and measurement techniques – Surge immunity test
    • IEC/EN 61000-4-6 Electromagnetic compatibility (EMC) – Part 4-6: Testing and measurement techniques – Immunity to conducted disturbances, induced by radio-frequency fields
    • IEC/EN 61000-4-8 Electromagnetic compatibility (EMC) – Part 4-8: Testing and measurement techniques – Power frequency magnetic field immunity test
    • IEC/EN 61000-4-11 Electromagnetic compatibility (EMC) – Part 4-11: Testing and measurement techniques – Voltage dips, short interruptions and voltage variations immunity tests
    • The Low Voltage Directive LVD 2006/95/EC Electrical equipment designed for use within certain voltage limits
    • Directive EMC 2004/108/EC on electromagnetic compatibility
    • IEC/EN 61010 Safety requirements for electrical equipment for measurement, control, and laboratory use – series
    • IEC/EN 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General requirements
    • IEC/EN 61010-031 Amendment 1 – Safety requirements for electrical equipment for measurement, control and laboratory use – Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement
    • IEC/EN 61010-2-032 Safety requirements for electrical equipment for measurement, control and laboratory use – Part 2-032: Particular requirements for hand-held and hand-manipulated current sensors for electrical test and measurement

    EMC safety

    • IEC/EN 61326 Electrical equipment for measurement, control and laboratory use – EMC requirements – series
    • IEC/EN 61326-1 Electrical equipment for measurement, control and laboratory use – EMC requirements – Part 1: General requirements

    Reviews

    There are no reviews yet

    Be the first to review “Metrel MD 9260 -| TRMS Photovoltaic Clamp Meter CAT III 1500 V DC”

    Need help? Call our support team 1800 358 531

    announcement  EOFY specials It's that time of the year again - the end of financial year! And here at MyMeter.